Some uplink distributed portgroup(s) on the source vCenter Server have NetFlow enabled.Make sure NetFlow is disabled and NetFlow Override port policies is disabled in the following uplink distributed portgroup(s) list.
VDS IPFix on Uplink Portgroups is not supported in VCF 9.1.
If VCF Operation for Networks is not upgraded to 9.1, this error may occur during the vCenter upgrade process. Upgrading VCF Operation for Networks to 9.1 is necessary.
Upgrading VCF to 9.1 has strict sequential requirements. VCF Operation for Networks must be upgraded before upgrading vCenter. Reference document: https://techdocs.broadcom.com/us/en/vmware-cis/vcf/vcf-9-0-and-later/9-1/deployment/upgrading-cloud-foundation.html
Upgrade VCF Operation for Networks to version 9.1 prior to the vCenter upgrade.
Afterward, the NetFlow configuration in vCenter VDS Uplink Portgroups will automatically disappear, and the vCenter upgrade will succeed.
This issue can also occur in instances where VCF Operations for Networks is upgraded to 9.1 prior to vCenter being upgraded but there were issues with the upgrade of vCenter Operations for Networks. If any of the following KB articles were used to address these issues, the NetFlow configuration may remain on vSphere Distributed Switches even after VCF Operations for Networks is upgraded to 9.1:
In this scenario, manual remediation is necessary.
Note: If VCF Operations for Networks is not deployed or the issue remains after the steps in the Resolution and Additional Information sections have been performed, address similar symptoms- check for active Netflow configurations on the vDS port groups. If Netflow is enabled, disable it to allow the vCenter upgrade to proceed successfully.