The AIX agent fails to start after an upgrade to version 24.4.5. The startup process terminates with the message: "Binary is running as sgid or suid, LIBPATH cannot be set." This prevents the loading of the libmanagement.so module, causing an initialization failure.
Symptoms:
java.lang.NoClassDefFoundError: java.lang.management.ManagementFactory initialization failure.UnsatisfiedLinkError regarding /jre/lib/libmanagement.so.This issue is identified as a product defect (DE210146) where the agent fails to start when executed as an unprivileged user with the SUID bit set and the binary owned by root.
This issue is targeted to be fixed in release 24.4.5 HF2 - TBA and 24.4.6 - TBA.
If you are experiencing this issue, please subscribe to this article () to be updated on fix status.
Once the fix is released, see for steps to download this release.
This also makes the workaround in KB article obsolete.