"IP Block Usage Very High" alarm is getting triggered even if IpBlock usage is low (even when usage is >= 50%)
search cancel

"IP Block Usage Very High" alarm is getting triggered even if IpBlock usage is low (even when usage is >= 50%)

book

Article ID: 320308

calendar_today

Updated On:

Products

VMware NSX

Issue/Introduction

  • IP Block Usage Very High alarm will be seen.
  • The observed IP block usage is not high, possibly under 50%.

Environment

VMware NSX
VMware NSX-T Data Center

Cause

Issue happens when multiple subnet been created using single Pool, then same subnet being getting added in blockUsage and causing alarm to trigger

Resolution

This issue is resolved in VMware NSX 4.2 and 3.2.4, available at Broadcom downloads.

If you are having difficulty finding and downloading software, please review the Download Broadcom products and software KB.

There is no functional impact.

Additional Information

IP Block Usage Very High alarm event in NSX 4.2 even if IpBlock usage is low