Issue/Introduction
Symptoms
The vSphere Client displays: Login to iSCSI target iqn.#### on vmhba## failed. The iSCSI initiator could not establish a network connection.
In /var/log/vobd.log, events similar to the following appear:
[iscsiCorrelator] [vob.iscsi.target.connect.error] vmhba## @ vmk# failed to login to iqn.#### because of a network connection failure. [iscsiCorrelator] [vob.iscsi.target.async.event] The target iqn.#### issued an async event for vmhba## with reason code 0003
Storage adapter paths show a state of "Dead" or "Offline".
Datastores may enter "All Paths Down" (APD) state.
VMs are in inaccessible state or stuck in boot loop.
Environment
VMware vSphere ESXi 7.x / 8.x
Cause
Improper storage array configuration, host networking mismatches, physical hardware failure (SFPs/Cabling), or MTU size inconsistencies across the fabric.
Resolution
Verify if the iSCSI initiator configuration is correct and ports are unbound/bound correctly.
Test connectivity using vmkping to the target portal: vmkping -I vmk# ###.###.###.### -d -s 1472
Ensure the storage device has a default gateway defined and can ping the host.
Verify MTU consistency (e.g., Jumbo Frames 9000) end-to-end.
Check physical link status on the storage array and network switch ports.
If reason code 0003 is present, engage the storage vendor to inspect for hardware or controller-side failures.