免責事項:これは英文の記事「Connection to iSCSI target fails due to network failure」の日本語訳です。記事はベストエフォートで翻訳を進めているため、ローカライズ化コンテンツは最新情報ではない可能性があります。最新情報は英語版の記事で参照してください。
症状:
Login to iSCSI target iqn.1992-08.com.netapp:sn.#### on vmhba40 failed. The iSCSI initiator could not establish a network connection to the target.
iscsiCorrelator] 535636694us: [vob.iscsi.target.connect.error] vmhba33 @ vmk2 failed to login to iqn.1992-08.com.netapp:sn.#### because of a network connection failure.
[iscsiCorrelator] 535637125us: [esx.problem.storage.iscsi.target.connect.error] Login to iSCSI target iqn.1992-08.com.netapp:sn.#### on vmhba33 @ vmk2 failed. The iSCSI initiator could not establish a network connection to the target.
In (14) vobd[2097763] :[iscsiCorrelator] 2164914633639us: [esx.problem. storage.iscsi.discovery. connect.error]iSCSI discovery 10.##.##.## on vmhba64 failed. The iSCSI Initiator could not establish a network connection to the discovery address.
In var/run/log/vobd.log - 2025-08-12T20:41:35.974Z: [APDCorrelator] 59896600757809us: [vob. storage. apd. start] Device or filesystem with identifier [naa. ####################] has entered the All Paths Down state.VMware vSphere ESXi 7.x
VMware vSphere ESXi 8.x
この問題は、ストレージ アレイ構成、ホスト ネットワーク構成、または環境全体に設定された MTU サイズを含む VMware ESXi 製品の設定が不適切であるために発生します。
接続エラーを解決するには:
[root@esxi01:~] vmkping -I vmk# 192.168.#.### -d -s 1472PING 192.168.#.### (192.168.#.###): 1472 data bytes
--- 192.168.#.### ping statistics ---3 packets transmitted, 0 packets received, 100% packet loss
iSCSI 接続の問題のトラブルシューティングの詳細については、「Troubleshooting ESXi connectivity to iSCSI arrays using software initiators」を参照してください。
ストレージおよびネットワーク ベンダーに連絡して、問題をさらに調査してください。