This article shows Network Failure Detection Policy - Link status only mode triggers conditions in detail and vSS/vDS Network uplink redundancy lost/degraded log records to prove it.
VMware ESXi 8.0.x
VMware ESXi 7.0.x
Network Failure Detection Policy - Link status only
Relies only on the link status that the network adapter provides. Detects failures, such as:
Link status does not detect the following configuration errors:
Alarms Network uplink redundancy lost/degraded Validation
Generally, if the Network Failure Detection Policy - Link status only is triggered, It also coexists with Alarms Network uplink redundancy lost/degraded
To validate Alarm Network uplink redundancy lost/degraded is triggered. We need to check as follows:
YYYY-MM-DDTHH:MM:SS.028Z: [netCorrelator] 47201977007087us: [vob.net.pg.uplink.transition.down] Uplink: vmnic2 is down. Affected portgroup: port_group. 1 uplinks up. Failed criteria: 128
YYYY-MM-DDTHH:MM:SS.028Z: [netCorrelator] 47201977007132us: [vob.net.vmnic.linkstate.down] vmnic vmnic2 linkstate down
YYYY-MM-DDTHH:MM:SS.028Z: [netCorrelator] 47201977007087us: [vob.net.pg.uplink.transition.down] Uplink: vmnic2 is down. Affected portgroup: port_group. 1 uplinks up.
YYYY-MM-DDTHH:MM:SS.028Z: [netCorrelator] 47201977007132us: [vob.net.vmnic.linkstate.down] vmnic vmnic2 linkstate down
YYYY-MM-DDTHH:MM:SS.028Z: [netCorrelator] 47201977007132us: [vob.net.vmnic.linkstate.down] vmnic vmnic2 linkstate down
For more information on Link status refer KB: Link state up or down for a vmnic interface on ESXi
For more information on Link status marked down because of a failed criteria code refer KB: Network adapter (vmnic) is down or fails with a Failed Criteria Code