Database Management for DB2 for Z/OS : Terminating a BATCH PROCESSOR ID that is flagged Incomplete due to message BPA0022E.
search cancel

Database Management for DB2 for Z/OS : Terminating a BATCH PROCESSOR ID that is flagged Incomplete due to message BPA0022E.

book

Article ID: 55017

calendar_today

Updated On:

Products

Database Management for DB2 for z/OS - Administration Suite

Issue/Introduction

How to terminate a BATCH PROCESSOR ID that is flagged incomplete as a result of an abend in a batch job when the following message is received:

BPA0022E: BPID IS FLAGGED INCOMPLETE - RESTART IS REQUIRED.

 



Environment

Release: R20
Component: RBP

Resolution

The Execution Display Facility within RC/Migrator is an online execution display of analysis and BATCH PROCESSOR jobs. It shows the progress of the job as it executes. When a job abends and is placed in "NI" status (Error during execution, job terminated) the following steps can be performed to terminate the BPID:

  1. Select RC/Migrator from the products main menu
  2. Select 3 - Execution Display (results in the following display)
PTEDL1        ------------ Execution Display Panel -----------
COMMAND ===>

BPID ==> *
DB2 SSID ==> ssid Strat Creator ==> * Timestamp ==> *
Status ==> * Strat Name ==> * Type ==> *
-----------------------------------------------------------------------
At this point, any of the selection criteria can be entered to limit the rows retrieved:
BPID: Specify the Batch Processor ID which appears in the JCL.
Strat Creator: Specify the creator of the strategy.
Timestamp: Specify a timestamp to limit the rows retrieved generated
during a particular time.
Status: Specify "NI".
Strat Name: Specify the name of the strategy.
Type: Specify, S, (Sync point)
A, (Analysis)
M, (Message record)
L, (Load record)

The selection criteria specified will then display the records that meet the selection parameters. Place a "D" (delete) next to the record to delete this entry from the log table. Proceed to restart the job with the appropriate restart parameter.

Additional Information

See Article ID: 54745 Restart of a Utility Execution during an execution of Batch Processor code. for more details on restarting stopped utilities. See Article Id: 52356 How to identify the restart point of a failed batch processor execution. regarding how to identify the restart point of a failed batch processor execution.