When creating an enhanced logmon profile in MCS it is not possible to select "QOS Metric Name" on the Variable Sub profile. The drop-down does not work.
If no Metric Name is established, the QOS cannot be stored to the DB so this creates an issue.
Environment
UIM 20.4.x
Logmon MCS Enhanced Template any version
Cause
Missing Logmon Enhanced Setup profile
Resolution
The QOS Name needs to be defined first in a child profile of "Setup Logmon"