Installing WinPE11 ADK for use in Deployment Solution 8.x
search cancel

Installing WinPE11 ADK for use in Deployment Solution 8.x

book

Article ID: 228797

calendar_today

Updated On:

Products

Deployment Solution

Issue/Introduction

Available versions of WinPE can be found on the following Microsoft page:

Download and install the Windows ADK

NOTE: WinPE 11 would not work (fail to build) on PXE Server with Windows Server version 2012 R2 due to Microsoft limitations. See linked KB 225580

Environment

Deployment Solution 8.x

Resolution

The following must be completed from the Notification Server / Symantec Management Platform while logged in as an Administrator:

  1. Uninstall any existing ADK's from the system through add/remove programs or by running the older ADK setup file(s) manually and choosing to Uninstall.
  2. The following table shows the supported versions of WinPE for Deployment Solution (for more details on Deployment Solution Support Matrix, please check here):

    This section shows the Windows 11 Pre-installation Environment (WinPE) versions supported in Deployment Solution 8.5 RU4, 8.6.x, and 8.7.x.

    Windows 10 Pre-installation Environment (WinPE)

    WinPE 11 version

    Deployment Solution version

    WinPE 11 21H2

    8.5 RU4, 8.6 RU1 

    WinPE 11 22H2 Starting from 8.7
    WinPE 10.1.25398.1 (September 2023) Starting from 8.7.2
    WinPE 10.1.26100.1 (May 2024/December 2024) * Starting from 8.7.3
       
    * ADK 10.1.26100.1 (May 2024) has been replaced by ADK 10.1.26100.2454 (December 2024) while keeping the same WinPE 10.1.26100.1 
  3. Download the appropriate ADK for the version of Deployment Solution being used:
    1. 8.x:  click here to download the Windows 11 21H2 build of the ADKWith build WinPE10 1809 and after, Microsoft split the Windows PE tools out of the ADK. After the ADK is installed, click here to download the Windows PE ADK add-on and install it (using the default settings). 
    2. 8.7.x: click here to download the latest WinPE 11 22H2 build of ADK, and after ADK is installed click here to download the WinPE ADK addon and install using default settings.
  4. Run the ADK setup file and install it to the default location on your SMP (Default Location: C:\Program Files (x86)\Windows Kits\10\), then click Next.
  5. Select  'Yes' or 'No' on the Windows Kits Privacy page and click Next.
  6. Accept the license agreement
  7. On the 'Select the features you want to install' page check only 'Deployment tools'.  (Older Versions pre-1809 of WinPE also checked 'Windows Preinstallation Environment (Windows PE)'    
  8. Click 'Install'
  9. Repeat Steps 4 - 8 for the Windows PE add-on
  10. Open the NS console and navigate to ‘Settings > All settings > Deployment > Preboot Configurations
  11. Click on the ‘Change WinPE’ drop down and select ‘WinPE 11.0
  12. The Win11 ADK import screen is shown.  If not, go to step #13 and modify the 'prebootos.ini' file.  The hyperlink under #1 will not be selectable because the WAIK has already been installed.
  13. Verify that the link 'Click here to import Windows ADK' is viewable and clickable. If it is not AND you have installed the appropriate ADK listed above, do the following in 8.6.x:
    1. Navigate to “<drive>:\Program Files\Altiris\Deployment\BDC\bootwiz” and open ‘prebootos.ini’.
    2. Modify the bolded lines to false. 

      [WINPE11_X86]
      OS=WINPE
      OS_SUBTYPE=WINPE11
      OS_SUBSUBTYPE=WINPE11
      PROCESSOR=X86
      INSTALLED=False
      ENABLED=True
      PXECREATE=True

      [WINPE11_X64]
      OS=WINPE
      OS_SUBTYPE=WINPE11
      OS_SUBSUBTYPE=WINPE11
      PROCESSOR=X64
      INSTALLED=False
      ENABLED=True
      PXECREATE=True

    3. Save the file.  Repeat steps #10-12 to try the Import again.
    4. Starting from Version 8.7 - from console Settings>Deployment>Manage Preboot Configurations in Preboot Environment Settings tab is now possible to Re-Import ADK install into DS:
  14. Click on 'Click here to import Windows ADK' to start the ADK import process. 
  15. Allow the ‘BDC’ package to update on all Package Servers
  16. Create/Recreate PXE preboots and/or automation folders with the new WinPE 11.

Note 1:  If there is a 'check mark' next to the preboot OS in bootwiz modify the 'prebootos.ini' as noted in Step #12 above.

Note 2: It may be necessary to remove the waik_winpe11 folder if the bootwiz.exe shows a checkmark next to the version and architecture to reinstall

           The waik_winpe11 is located in <install drv>:\Program Files\Altiris\Deployment\BDC

Additional Information

150348 "Installing WinPE10 ADK for use in Deployment Solution 8.x"

225580 "Can the latest WinPE 11 ADK be used with the latest version of DS and GSS"