If the notification database has an excessively high number of pending notifications that are no longer required, you can clear them at once using the dxemptydb tool. This procedure applies to the Virtual Appliance 14.5 Linux environment.
Virtual Appliance 14.5
The notification DSA (Directory System Agent) queue may become overloaded due to backlogs, leading to excessive pending notifications that are of no importance.
Warning: Clearing the notification database will lead to data loss. Updates from the Provisioning Server will not be applied to the Identity Manager server, and there is no automatic way to resync the two layers.
dsa user: su - dsadxserver status Example output: ca-prov-srv-01-impd-notify stoppeddxserver stop ca-prov-srv-01-impd-notifydxemptydb ca-prov-srv-01-impd-notify (You should see the message "Successfully created")dxserver start ca-prov-srv-01-impd-notifyetanotify log: /opt/CA/IdentityManager/ProvisioningServer/logsobjectclass=eTDomainComponent.If you are running on Windows, see the article How to clear Provisioning Server notification queue (inbound synchronization)
To speak with a customer representative or a Support Engineer see . Scroll to the bottom of the page and click on your respective region.