The "Datastore usage on disk" alarm triggers in vCenter Server when storage consumption exceeds preconfigured thresholds (Warning: 75%; Critical: 85%). This article outlines how to validate these alerts, resolve capacity issues, and address "stale" alarm states.
VMware vCenter Server 7.x, 8.x
VMware vSphere ESXi 7.x, 8.x
Default vCenter alarm definitions trigger alerts. If storage usage is below the configured thresholds, the alarm may be "stale" due to a known desynchronization issue in vCenter 7.x/8.x.
vSphere Client.Monitor > Performance tab to verify current usage.If usage is below thresholds but the alarm persists:
vCenter Server > Configure > Alarm Definitions.Datastore usage on disk alarm.If the default thresholds do not match environment requirements:
Alarm Definitions as described above.Datastore usage on disk alarm to adjust the Warning and Critical percentage values.