After upgrading to SGOS 7.4.14 and later, an increased number of IWA health check failures occur. This issue appears after enabling the optimize-dc feature, resulting in "sick" status alerts, AUTH_EVENT_SCHANNEL_DC_CONNECTED log spam, and Schannel Resets.
optimize-dc enabledA defect in the optimize-dc feature causes a session key overwrite. When the appliance tests the currently connected DC, it instantiates a new connection. This overwrites the active Schannel session key for the machine account, invalidating the session key held by the primary server handling live NTLM authentications .
This issue is confirmed as a product defect.
Workaround: If upgrading to SGOS 7.4.14.3, use one of the following methods to mitigate the issue:
optimize-dc feature disabled.Fix Status: Targeted to be fixed in a future SGOS release. Subscribe to this article (reference: ) to receive updates on the fix status.