The probe_discovery queue is stuck and continues to grow, reaching over 500,000 queued messages while processing very few.
DX UIM 23.4CU7 and Earlier
High frequency of device attribute changes (multiple MAC/IP addresses) triggering excessive re-correlation events and a product defect in how discovery_server handles these recreation events can cause these issues in Large Scale Environments.
Deploy Discovery Server Patch
Install the discovery_server_23.4.3.4.zip patch which contains code enhancements to handle re-correlation events more efficiently. This fix ensures that incoming devices with high attribute volatility do not impact overall probe performance.
NOTE this patch is valid for DX UIM 23.4CU4.
discovery_server raw configuration:setup > db_connection_pool_max_idle = 50setup > db_connection_pool_size = 50Related KB:
NOTE:
The fix is NOT present in DX UIM 23.4.CU5/CU6/CU7/CU8 GA. The will be included in CU9. If a fix is needed for pre CU9, Contact Broadcom support