vSAN Disk Group reports Permanent Device Loss (PDL) on Lenovo ThinkSystem while XCC Console shows Healthy
search cancel

vSAN Disk Group reports Permanent Device Loss (PDL) on Lenovo ThinkSystem while XCC Console shows Healthy

book

Article ID: 441026

calendar_today

Updated On:

Products

VMware vSAN VMware vSphere ESXi

Issue/Introduction

Symptoms:

  • vSAN Skyline Health triggers a critical alert: "Disk group unhealthy" or "Permanent disk loss."
  • The vSAN Disk Group status appears as Offline or Absent in the vSphere Client.
  • Lenovo XCC (XClarity Controller) or hardware management consoles report no physical disk failures or predictive alerts.
  • Virtual machines remain accessible if they have compliant storage policies (FTT=1 or higher), but the cluster reports a "Risk of data unavailability" due to reduced redundancy.

Environment

vSphere vSAN Original Storage Architecture (OSA) 8.x

Cause

This issue occurs when an NVMe storage device experiences a fatal controller or firmware-level lockup.

  1. Logical Ejection: The ESXi nvme driver identifies a fatal status and attempts to reset the controller. If the hardware fails to respond to the reset, the ESXi kernel logically ejects the device as a "Hot Remove" event to prevent the storage stack from hanging. Following events can be noticed in the vmkernel logs.
    • ESXi Kernel detecting fatal hardware status and issuing a controller reset:

      YYYY-MM-DDTHH:MM:SS.Z In(182) vmkernel: cpu64:#####)nvme_TaskMgmt: adapter:5 fatal status, reset controller
      YYYY-MM-DDTHH:MM:SS.Z In(182) vmkernel: cpu64:#####)nvme_ResetController: adapter:5

    • NVMe controller reset failure and logical device ejection (Hot Removed):

      YYYY-MM-DDTHH:MM:SS.Z In(182) vmkernel: cpu65:#####)nvme_ResetController: adapter:5 failed to start, marking as failed
      YYYY-MM-DDTHH:MM:SS.Z In(182) vmkernel: cpu65:#####)####:##:##.# vmd_ScsiSetPathLostByDevice: Lost SCSI path: target(0)->(1) lun(#########)
      YYYY-MM-DDTHH:MM:SS.ZIn(182) vmkernel: cpu65:#####)rpVmk_ScsiSetPathLostByDevice: Hot Removed Disk SerialNo:############ ############

  2. Deduplication Impact: In vSAN Original Storage Architecture (OSA) clusters with Deduplication and Compression enabled, the loss of any single capacity drive invalidates the entire disk group's hash table. vSAN must then mark the entire disk group as DISKGROUP_UNDER_PDL.

    • vsandevicemonitor logs show "DISKGROUP_UNDER_PDL" because deduplication is enabled.

      YYYY-MM-DDTHH:MM:SS.Z In(14) vsandevicemonitord[2100930]: [########]: Device t10.NVMe____###########... state is DISKGROUP_UNDER_PDL
  3. XCC Discrepancy: The Lenovo XCC does not display an alert because the OS-level driver timeout and logical ejection occur without triggering the physical sensors monitored by the out-of-band BMC.

Resolution

  1. Check the health of the vSAN objects by navigating to the vSAN cluster in the vSphere Client and going to Monitor > vSAN > Virtual Objects. If the health status of any objects is Reduced availability or Inaccessible, do not proceed and contact Broadcom Support.

  2. If the objects are healthy, navigate to the vSAN cluster in the vSphere Client. Go to Configure > vSAN > Disk Management.

  3. Select the affected ESXi host and locate the unhealthy disk group.

  4. Click Remove. Select the Ensure accessibility option first to attempt graceful maintenance. If this task fails or hangs, contact Broadcom Support for further assistance.
  5. If the "Remove" is successful, replace the failed NVMe drive following Lenovo hardware replacement procedures. Verify the new drive is detected in the Storage > Devices view of the ESXi host.

  6. Return to vSAN > Disk Management for the affected host. Click Create Disk Group.

  7. Select the original cache device and the new replacement capacity device. vSAN will automatically format the drives and apply the cluster's deduplication and compression settings.

Additional Information

Troubleshooting vSAN OSA disk issues

Replace a Capacity Device in vSAN Cluster