vSphere vSAN Original Storage Architecture (OSA) 8.x
This issue occurs when an NVMe storage device experiences a fatal controller or firmware-level lockup.
nvme driver identifies a fatal status and attempts to reset the controller. If the hardware fails to respond to the reset, the ESXi kernel logically ejects the device as a "Hot Remove" event to prevent the storage stack from hanging. Following events can be noticed in the vmkernel logs.YYYY-MM-DDTHH:MM:SS.Z In(182) vmkernel: cpu64:#####)nvme_TaskMgmt: adapter:5 fatal status, reset controllerYYYY-MM-DDTHH:MM:SS.Z In(182) vmkernel: cpu64:#####)nvme_ResetController: adapter:5
NVMe controller reset failure and logical device ejection (Hot Removed):
YYYY-MM-DDTHH:MM:SS.Z In(182) vmkernel: cpu65:#####)nvme_ResetController: adapter:5 failed to start, marking as failedYYYY-MM-DDTHH:MM:SS.Z In(182) vmkernel: cpu65:#####)####:##:##.# vmd_ScsiSetPathLostByDevice: Lost SCSI path: target(0)->(1) lun(#########)YYYY-MM-DDTHH:MM:SS.ZIn(182) vmkernel: cpu65:#####)rpVmk_ScsiSetPathLostByDevice: Hot Removed Disk SerialNo:############ ############
YYYY-MM-DDTHH:MM:SS.Z In(14) vsandevicemonitord[2100930]: [########]: Device t10.NVMe____###########... state is DISKGROUP_UNDER_PDLCheck the health of the vSAN objects by navigating to the vSAN cluster in the vSphere Client and going to Monitor > vSAN > Virtual Objects. If the health status of any objects is Reduced availability or Inaccessible, do not proceed and contact Broadcom Support.
If the "Remove" is successful, replace the failed NVMe drive following Lenovo hardware replacement procedures. Verify the new drive is detected in the Storage > Devices view of the ESXi host.
Return to vSAN > Disk Management for the affected host. Click Create Disk Group.
Select the original cache device and the new replacement capacity device. vSAN will automatically format the drives and apply the cluster's deduplication and compression settings.