Unable to take backups and Backup Proxy VMs hang due to vSAN component exhaustion from orphaned PVC/FCD objects
search cancel

Unable to take backups and Backup Proxy VMs hang due to vSAN component exhaustion from orphaned PVC/FCD objects

book

Article ID: 440566

calendar_today

Updated On:

Products

VMware vSAN VMware vSphere ESXi

Issue/Introduction

  • Rapid/unusual increase of number of orphaned First Class Disks (FCD) or Persistent Volume Claims (PVC) objects is observed.

  • Backup Proxy servers in a vSAN environment intermittently enter a hung or unresponsive state, leading to backup job failures.

  • Backup Proxy VMs are unresponsive or intermittently hung.

  • vSAN Skyline Health reports "Red" status for "Cluster and Host Component utilization".

  • Component utilization exceeds 100% (e.g., 106%).

  • New snapshots fail to be created.

Environment

VMware vSphere vSAN

Cause

In vSAN Original Storage Architecture (OSA), each host has a hard metadata limit of 9,000 components. When total component utilization exceeds 100% for any reason, vSAN cannot allocate new components for snapshots or I/O operations, leading to queue exhaustion and VM unresponsiveness.

Unexpected and rapid increase in component utilization is usually caused by a combination of disk/snapshot provisioning automation and frequent network flapping.

For example: when CSI Driver/Backup API calls/PowerCLI createDisk_Task methods fail mid-flight (and are retried) repeatedly against storage that changes status (online/offline) rapidly.

Resolution

If standard reconciliation via the ReconcileDatastoreInventory task does not reclaim components, manual cleanup of orphaned objects might be required.

  1. Collect a full support bundle and identify orphaned PVC objects by comparing the active Kubernetes PV list against the vCenter cns.volume_info table.
  2. Identify physical backing files (.vmdk) in the fcd folder on the vSAN datastore that have no corresponding active PVC.
  3. Use the objtool utility to remove orphaned vSAN objects. It is recommended to test the removal on a small subset (e.g., 100 objects) before proceeding with a full cleanup.
  4. Remove associated .vmdk and .vmfd files from the ESXi host.
  5. Remove stale volume IDs from the vCenter database.
  6. Initiate a vSAN object reconciliation process and wait for the operation to complete.
  7. Verify that vSAN component utilization has dropped within architectural limits (under 90%).

For assistance with manual database or object removal, contact Broadcom Support. See Contact Broadcom Support.

Additional Information

For more information on the reconciliation process, refer to KB 321994. To stay updated on this article, see How to subscribe to Broadcom Knowledge Base articles.

For detailed guidance and instructions on using the objtool utility, please refer to the Knowledge Base article: 

vSAN on-disk format upgrade to version 20 fails due to inaccessible objects

vSAN Health Service - Data Health - vSAN Object Health - inaccessible objects