SRM Planned Migration fails at Change Storage to Read Only during Datastore Unmount with Array-Based Replication
search cancel

SRM Planned Migration fails at Change Storage to Read Only during Datastore Unmount with Array-Based Replication

book

Article ID: 438724

calendar_today

Updated On:

Products

VMware Live Recovery

Issue/Introduction

During the execution of a VMware Live Recovery (SRM) planned migration recovery plan, the workflow fails at the Change Storage to Read Only step.

This failure occurs during the datastore unmount operation for virtual machines utilizing Array-Based Replication (ABR) with storage adapters such as Dell EMC SRA.

Symptoms:

  • SRM recovery plan fails with a timeout error after 1,080 seconds.
  • From vmware-dr.log on the SRM appliance you may see this error: Failed to unmount VMFS datastores - Timed out 1080 seconds.
  • ESXi hostd.log entries may indicate underlying storage connectivity issues: could not issue sync IO command: No connection.
  • Array pairs may show healthy, but specific ESXi hosts fail to release the LUNs.

 

Environment

VMware Site Recovery Manager 8.x

VMware Live Site Recovery 9.0.x

VCF Protection and Recovery 9.1.x

Dell EMC Storage Replication Adapter

Cause

 

The SRM recovery plan failure is caused by an underlying storage connectivity issue on one or more ESXi hosts in the cluster.

A hung I/O or "No connection" state on the storage paths prevents the host from processing the synchronous I/O commands required to successfully unmount replicated VMFS datastores during the planned migration workflow.

Validation:

From hostd.log, you may see the below event:

2026-04-29T04:21:59.689Z In(166) Hostd[2100230]: [Originator@6876 sub=Vimsvc.ha-eventmgr] Event 3808 : Issue detected on a#####.e###.w####.####.com.## in ha-datacenter: PowerPath:EKBE003: Path vmhba##:CO:T9:L6 : could not issue sync IO command: No connection

Resolution

The affected ESXi host(s) must be remediated to clear the stale I/O state before the SRM workflow can proceed.

Recommend engaging the storage vendor for further assistance.

Once the affected ESXi host is remediated, re-run the recovery plan operation.

Additional Information

Reference KB articles:

PowerPath Common Error Code Reference Guide

Error EKBE003 from PowerPath