During the execution of a VMware Live Recovery (SRM) planned migration recovery plan, the workflow fails at the Change Storage to Read Only step.
This failure occurs during the datastore unmount operation for virtual machines utilizing Array-Based Replication (ABR) with storage adapters such as Dell EMC SRA.
VMware Site Recovery Manager 8.x
VMware Live Site Recovery 9.0.x
VCF Protection and Recovery 9.1.x
Dell EMC Storage Replication Adapter
The SRM recovery plan failure is caused by an underlying storage connectivity issue on one or more ESXi hosts in the cluster.
A hung I/O or "No connection" state on the storage paths prevents the host from processing the synchronous I/O commands required to successfully unmount replicated VMFS datastores during the planned migration workflow.
From hostd.log, you may see the below event:
2026-04-29T04:21:59.689Z In(166) Hostd[2100230]: [Originator@6876 sub=Vimsvc.ha-eventmgr] Event 3808 : Issue detected on a#####.e###.w####.####.com.## in ha-datacenter: PowerPath:EKBE003: Path vmhba##:CO:T9:L6 : could not issue sync IO command: No connection
The affected ESXi host(s) must be remediated to clear the stale I/O state before the SRM workflow can proceed.
Recommend engaging the storage vendor for further assistance.
Once the affected ESXi host is remediated, re-run the recovery plan operation.