Failed to init PSC and/or Postgres. Check the SDDC Manager UI Server logs for more details."というエラーが表示される。VMware Cloud Foundation is initializing"というエラーが表示される。/var/log/vmware/vcf/sddc-manager-ui-app/sddcManagerServer.log に以下のログが記録される。yyyy-mm-ddThh:mm:ss.mss+0000 VERBOSE [a4c53bab982c432c, 3878912b2d1849e4, d7705f9eba5a4aa5] [services/logging/opentrace.js, init-pscs-primary, _finish:231] Span init-pscs-primary complete: Total time: 2511ms {"duration":2511}
yyyy-mm-ddThh:mm:ss.mss+0000 ERROR [a4c53bab982c432c, 3878912b2d1849e4] [services/pscUtils.js, init-pscs, attemptPSCInit:67] Caught error from await primaryPscInit
yyyy-mm-ddThh:mm:ss.mss+0000 WARN [a4c53bab982c432c, 3878912b2d1849e4] [services/pscUtils.js, init-pscs, attemptPSCInitWithRetry:111]
100.109: VError: PSC Initilization attempt "6" failed: Failed to initiate PSC: Primary psc init failed and failover psc init also failed: Unable to retrieve iDP Metadata: Request failed with status code 500
at Object.initializationPscError (/opt/vmware/vcf/sddc-manager-ui-app/server/src/errors/VCFError.js:104:5)
at attemptPSCInitWithRetry (/opt/vmware/vcf/sddc-manager-ui-app/server/src/services/pscUtils.js:104:46)
at process.processTicksAndRejections (node:internal/process/task_queues:95:5)
Error Info: {"retryCount":6,"status":403,"errorModule":100,"errorCode":109,"code":"ERR_BAD_RESPONSE"}
caused by:
100.108: VError: Failed to initiate PSC: Primary psc init failed and failover psc init also failed: Unable to retrieve iDP Metadata: Request failed with status code 500
at Object.initiatePscError (/opt/vmware/vcf/sddc-manager-ui-app/server/src/errors/VCFError.js:104:5)
at attemptPSCInit (/opt/vmware/vcf/sddc-manager-ui-app/server/src/services/pscUtils.js:72:26)
at process.processTicksAndRejections (node:internal/process/task_queues:95:5)
at async attemptPSCInitWithRetry (/opt/vmware/vcf/sddc-manager-ui-app/server/src/services/pscUtils.js:99:17)
Error Info: {"errorModule":100,"errorCode":108,"code":"ERR_BAD_RESPONSE"}/var/log/vmware/vcf/sddc-manager-ui-app/sddcManagerServer.log に以下のログが記録される。YYYY-MM-DDTHH:MM:SS:08.832634+00:00 ap-sy5-vcf sddc-manager-ui-app[70645]: /opt/vmware/vcf/sddc-manager-ui-app/server/src/services/sso-initialization.js:275この問題により、VCF Fleet managementがタスクの取得に失敗し、"Retrieving task counts failed. Http failure response for https://<Ops_FQDN>/vcf-operations/plug/sddc-###/plugin/api/v1/tasks?pageSize=1: 503 OK" というエラーが発生する場合がある。
YYYY-MM-DDTHH:MM:SS:08.832979+00:00 ap-sy5-vcf sddc-manager-ui-app[70645]: timeout = setTimeout(reject, sshCommandTimeout, new Error(failureMessage));
YYYY-MM-DDTHH:MM:SS:08.833032+00:00 ap-sy5-vcf sddc-manager-ui-app[70645]: ^
YYYY-MM-DDTHH:MM:SS:08.833078+00:00 ap-sy5-vcf sddc-manager-ui-app[70645]: Error: Remote ssh command timed out
YYYY-MM-DDTHH:MM:SS:08.833114+00:00 ap-sy5-vcf sddc-manager-ui-app[70645]: at /opt/vmware/vcf/sddc-manager-ui-app/server/src/services/sso-initialization.js:275:65
YYYY-MM-DDTHH:MM:SS:08.833149+00:00 ap-sy5-vcf sddc-manager-ui-app[70645]: at new Promise (<anonymous>)
YYYY-MM-DDTHH:MM:SS:08.833177+00:00 ap-sy5-vcf sddc-manager-ui-app[70645]: at init (/opt/vmware/vcf/sddc-manager-ui-app/server/src/services/sso-initialization.js:274:24)
YYYY-MM-DDTHH:MM:SS:08.833205+00:00 ap-sy5-vcf sddc-manager-ui-app[70645]: at Object.reset (/opt/vmware/vcf/sddc-manager-ui-app/server/src/services/sso-initialization.js:294:13)
YYYY-MM-DDTHH:MM:SS:08.833250+00:00 ap-sy5-vcf sddc-manager-ui-app[70645]: at initializeSSO (/opt/vmware/vcf/sddc-manager-ui-app/server/src/services/sso-initialization.js:60:24)
YYYY-MM-DDTHH:MM:SS:08.833291+00:00 ap-sy5-vcf sddc-manager-ui-app[70645]: at process.processTicksAndRejections (node:internal/process/task_queues:95:5)
YYYY-MM-DDTHH:MM:SS:08.833335+00:00 ap-sy5-vcf sddc-manager-ui-app[70645]: Node.js v18.20.4
YYYY-MM-DDTHH:MM:SS:08.832229+00:00 ap-sy5-vcf sddc-manager-ui-app[70645]: /opt/vmware/vcf/sddc-manager-ui-app/server/src/services/sso-initialization.js:275
YYYY-MM-DDTHH:MM:SS:08.832229+00:00 ap-sy5-vcf sddc-manager-ui-app[70645]: timeout = setTimeout(reject, sshCommandTimeout, new Error(failureMessage));
YYYY-MM-DDTHH:MM:SS:08.832229+00:00 ap-sy5-vcf sddc-manager-ui-app[70645]: ^
YYYY-MM-DDTHH:MM:SS:08.832229+00:00 ap-sy5-vcf sddc-manager-ui-app[70645]: Error: Remote ssh command timed out
YYYY-MM-DDTHH:MM:SS:08.832229+00:00 ap-sy5-vcf sddc-manager-ui-app[70645]: at /opt/vmware/vcf/sddc-manager-ui-app/server/src/services/sso-initialization.js:275:65
YYYY-MM-DDTHH:MM:SS:08.832634+00:00 ap-sy5-vcf sddc-manager-ui-app[70645]: /opt/vmware/vcf/sddc-manager-ui-app/server/src/services/sso-initialization.js:275
VCF 5.x
VCF 9.x
systemctl restart sddc-manager-ui-app
TOKEN=$(curl -d '{"username" : "<sso username>", "password" : "<sso password>"}' -H "Content-Type: application/json" -X POST http://127.0.0.1/v1/tokens | jq -r '.accessToken')curl -X GET 'localhost/v1/system/credentials?entityType=VCENTER&credentialType=SSH' -H 'Content-Type: application/json' -H "Authorization: Bearer $TOKEN"curl -X PUT 'localhost/v1/system/credentials/<id from above step>' -d '<new password>' -H "Content-type:application/json" -H "Authorization: Bearer $TOKEN"| json_ppsystemctl restart sddc-manager-ui-app