The following alarms or events are triggered in the NSX Manager UI:
Alarm Title: Alarm for Edge NIC out of receive buffer OR Alarm for Edge NIC out of transmit buffer
Event ID: edge_health.edge_nic_out_of_receive_buffer / edge_health.edge_nic_out_of_transmit_buffer
Product: VMware NSX
Component: NSX Edge Node (VM)
Process / Feature: Datapath Network Interfaces (RX/TX Ring Buffers)
Network traffic volumes exceed the default receive (RX) or transmit (TX) ring buffer capacity on the Edge node datapath interface, causing dropped packets and buffer exhaustion alarms.
Important: Changing the ring buffer size requires placing the NSX Edge node into Maintenance Mode, which temporarily stops the dataplane process and triggers a failover to the active peer in an HA configuration. Perform these steps during a scheduled maintenance window or one node at a time in an HA cluster.
Place the Target Edge Node into Maintenance Mode Place the specific Edge VM into NSX Maintenance Mode (via NSX Manager UI or CLI) to safely pause the data plane service and shift traffic to the passive node.
Configure the Ring Buffer Sizes Log into the CLI of the target Edge VM as an administrative user and adjust the receive and transmit ring buffer values.
Note: Buffer sizes must be increased in increments of
1024(e.g.,2048,3072,4096).
Execute the following commands:
set dataplane ring-size rx <new_ring_size>
set dataplane ring-size tx <new_ring_size>
Example:
set dataplane ring-size rx 4096
set dataplane ring-size tx 4096
Exit Maintenance Mode Bring the Edge node back online by exiting Maintenance Mode via the NSX Manager UI or CLI.
Verify the Configuration Confirm that the updated buffer sizes have been applied successfully:
get dataplane | find ring
If the output reflects the new values: The update is complete.
If the output does not reflect the new values: Reboot the Edge VM to force the datapath service to re-initialize with the updated parameters.
Repeat for High Availability Peers Repeat Steps 1 through 4 for each remaining Edge node in the cluster.
VMware Technical Documentation: NSX Edge Maintenance Mode
KB 311846: Entering and exiting NSX Edge Maintenance Mode via CLI