In some NSX environments, connectivity between Tier-0 and the uplink device can be lost, leading to an outage or severe slowness for workloads behind the Tier-0 VRF.
NOTE: Consider this issue if the environment was upgraded from NSX 3.1.x to 3.2.x or 4.x, and the same VLAN segment is used for both a T0 uplink and a T1 service interface on the same edge
VMware NSX-T 3.x
VMware NSX 4.1.x
Validation of 'two interfaces are connected to the same VLAN segment and both interfaces belong to the same edge VM' did not hit.
During the UFO data migration upgrade, the logical router port relationship is not created properly with logical switch UUID.
Ideally the relationship should have been created as UUID based instead it might have been created with string id.
This issue is resolved in VMware NSX 4.2.1.2, 4.2.2, 9.0, available at Broadcom downloads.
If you are having difficulty finding and downloading software, please review the Download Broadcom products and software KB.
Workaround:
Do a simple update on the interfaces for both Tier0 & Tier1 (e.g. add some description).