Cannot enable changed block tracking and multi-writer sharing at the same time. Failed to start the virtual machine. Module Disk power on failed. Cannot open the disk '/vmfs/volumes/<folder>/<VM_name>.vmdk' or one of the snapshot disks it depends on. One of the parameters supplied is invalid"
This issue has been seen when both SCSI Bus-sharing and Changed-Block Tracking (CBT) are enabled on a virtual machine at the same time.
VMs with SCSI Bus-sharing do not support snapshots, thus consequently configuring CBT as a snapshot feature is not supported for such virtual machines either.
To resolve this issue, make sure to disable Changed-Block Tracking for the affected virtual machine by following the steps documented in Enabling or disabling Changed Block Tracking (CBT) on virtual machines
Once CBT has been disabled, the VM should power on successfully.
For further assistance, contact Broadcom support.
See also Unable to use Snapshots or perform a backup on virtual machines configured with bus-sharing.