When attempting to perform a conversion the workflow fails with error: "A file I/O error occurred while accessing "."
search cancel

When attempting to perform a conversion the workflow fails with error: "A file I/O error occurred while accessing "."

book

Article ID: 424157

calendar_today

Updated On:

Products

VMware vCenter Server Converter VMware vSphere ESXi

Issue/Introduction

  • When attempting to perform a conversion, the workflow fails with the error:

    A file I/O error occurred while accessing ".



  • Logs show the following errors:

    vmware-converter-worker.log 
    <Time Stamp> warning vmware-converter-worker[33888] [Originator@6876 sub=Default] [,0] [NFC ERROR]Nfc_BindAndEstablishAuthdCnx3: Failed to create a connection with server <Destination_ESXi_Host>: Failed to connect to server <Destination_ESXi_Host>:902 
    <Time Stamp> info vmware-converter-worker[33888] [Originator@6876 sub=Default] Sysimgbase_DiskLib_OpenWithPassPhrase failed with 'NBD_ERR_NETWORK_CONNECT' (error code:2338)
    <Time Stamp> warning vmware-converter-worker[33888] [Originator@6876 sub=Default] [,0] [NFC ERROR]NfcNewAuthdConnectionEx: Failed to connect: Failed to connect to server <Destination_ESXi_Host>:902
    <Time Stamp> warning vmware-converter-worker[33888] [Originator@6876 sub=Default] [,0] [NFC ERROR]NfcNewAuthdConnectionEx: Failed to connect to peer. Error: Failed to connect to server <Destination_ESXi_Host>:902
    <Time Stamp> warning vmware-converter-worker[33888] [Originator@6876 sub=Default] [,0] [NFC ERROR]NfcEstablishAuthCnxToServer: Failed to create new AuthD connection: Failed to connect to server <Destination_ESXi_Host>:902
    ..
    <Time Stamp> error vmware-converter-worker[70384] [Originator@6876 sub=Default] [BaseDiskSetComputer::AnalyzeErrorAndThrow] Error occurred when opening disk set, MNTAPI_ERROR = 37409 MNTAPI errorType = 1, errorCode = 2338
    <Time Stamp> error vmware-converter-worker[70384] [Originator@6876 sub=Default] AnalyzeErrorAndThrow(): Opening virtual disk failed with error 'NBD_ERR_NETWORK_CONNECT' (error code:2338)
    <Time Stamp> error vmware-converter-worker[70384] [Originator@6876 sub=Default] TargetVmManagerImpl::CreateVM: Failed to retrieve the storage mapping with error Fault cause: converter.fault.FileIOFault

Environment

VMware vCenter Converter Standalone

Cause

The above error suggests a communication problem between the Converter server and the ESXi hosts on port 902.

That could be related to various reasons, including:

  • Physical network misconfiguration
  • Firewall / SSL inspection / Antivirus tool blocking the traffic on TCP port 902
  • Renewed ESXi Certificates

Resolution

Engage your Network Team to investigate the traffic between the Converter server, the ESXi host and the Source Machine on port TCP 902

Renewed ESXi Certificates –

    • In the vCenter Server inventory UI, right-clicked the affected ESXi host ➔ Connection ➔ Disconnect.
    • Right-clicked the host again ➔ Connection ➔ Reconnect (forcing vCenter to push a freshly signed, trusted VMCA certificate to the host).
    • Retry conversion

Additional Information

vCenter Converter Standalone - TCP/IP and UDP Port Requirements for Conversion

V2V Conversion Fails with Error “Failed: A File I/O Error Occurred While Accessing” in VMware vCenter Converter