Deployments are failing from Aria Automation after VCHA and NSX Manager restored from backup.
search cancel

Deployments are failing from Aria Automation after VCHA and NSX Manager restored from backup.

book

Article ID: 413484

calendar_today

Updated On:

Products

VCF Operations/Automation (formerly VMware Aria Suite)

Issue/Introduction

Deployments are failing from Aria Automation after VCHA restore from backup with error message "Provisioning operation failed. Could not find network with switch id <Switch-id> among target domain networks after 12 tries"

 

 

Environment

Aria Automation 8.18.1

Cause

 VCHA and NSX managers were  restored  days before the issue occurred. 
 

Details: A mismatch in moRef and portGroupKey for DVPGs caused by a NSX restore from backup caused the problem

Possible data corruption during the NSX Restore process.

Resolution

New code fix Created and delivered.

Instructions for application and the patch is details: https://knowledge.broadcom.com/external/article/403690

 

Additional Information

Accessing this patch file for Patch 3 requires  login to the BC Support portal. 

Instructions  for locating the Patch: https://knowledge.broadcom.com/external/article/369772.