After the upgrade from a previous release, the following errors are occurring when accessing the Spool menu:
PE FROM COMMAND INTERFACE
PEPE FROM COMMAND INTERFACE
Spool
There was a user library with an old ESFSSSM module in the STEPLIB concatenation of the Spool started task.
Remove the old ESFSSSM module from the STEPLIB concatenation and follow the procedure below:
1) Issue the following command:
F caspoolstc,REINIT,MODULES,ON
Where caspoolstc is the name of the Spool started task
The following message should appear after this command is issued:
ESF888 REINIT MODULES PROCESSED - REFRESH PENDING
2) Stop and start the Spool started task.
The following message should appear during the restart:
ESF022 MODULE REFRESH PERFORMED
A similar error may occur if maintenance is applied to OM Spool. Refer to the document below:
Error in Spool Menu after having applied maintenance: OPEN FAILED CODES: 'PEPE'