Unable to place vSAN host in full evacuation maintenance mode
search cancel

Unable to place vSAN host in full evacuation maintenance mode

book

Article ID: 393086

calendar_today

Updated On:

Products

VMware vSAN

Issue/Introduction

When running a precheck on a host in a four node vSAN cluster to place it into a full evacuation maintenance mode the error 1 more standalone host is required is returned

 

Environment

VMware vSAN 7.x

VMware vSAN 8.x

Cause

When checking the vSAN objects it was determined that the host still contained objects using a raid 5 storage policy, which requires 4 active hosts.

Resolution

The objects will need to wither be converted to raid 1 or if the object is no longer required deleted from the cluster.

Follow the steps here to change the storage policy for the devices:

Using vSAN storage policies

 

To identify the objects to determine if they are no longer needed follow the steps found here:

Procedures for identifying Unassociated vSAN objects.

Note: Open a case with vSAN Support for assistance with deleting unassociated objects