VMware Aria Operations 8.17 Hot Fix 3
search cancel

VMware Aria Operations 8.17 Hot Fix 3

book

Article ID: 373982

calendar_today

Updated On:

Products

VMware Aria Suite

Issue/Introduction

VMware Aria Operations 8.17 Hot Fix 3 is a public Hot Fix that addresses the following issues:

  • In case of Metric chart Metrics mode, for deleted object widget is throwing exception.
  • [Orphaned and Unassigned page] Dashboard loading takes ~3,9 min
  • [Platform] Custom and Dynamic properties starting to be unavailable in Object's metric picker after the Aria Operations upgrade from the older version to 8.17.x
  • Alerts: Super Metric name is not initialized in the alert details window
  • In scaled environments, the 'Content Management > Export' feature gets stuck when 'Application Definition Assignments' is marked.
  • Cost Calculation fails with NullPointerException

 

There have been no additional CVEs resolved in this hot fix.

Environment

VMware Aria Operations 8.17.x

Resolution

VMware Aria Operations 8.17 Hot Fix 3 can be applied to any 8.17.x environment.
Note: Upgrading from older versions directly to this Hot Fix is not supported.  You must upgrade to 8.17.x before applying this Hot Fix.

Important: Take snapshots of each of the VMware Aria Operations nodes before applying the Hot Fix by following How to take a Snapshot of VMware Aria Operations.

  1. Download the VMware Aria Operations 8.17 Hot Fix 3 PAK file from the Broadcom Support Portal.

Note: You will need to login to the portal first in order to allow download of the file when using the direct link below.

Release Name Release Date Build Number UI Build Number File Name
VMware-Aria-Operations-8.17-HF3 8/8/2024 24172044  24172048 vRealize_Operations_Manager_With_CP-8.10.x-to-8.17.2.24172044.pak
  1. Log in to the primary node VMware Aria Operations Administrator interface of your cluster at https://primary-node-FQDN-or-IP-address/admin .
  2. Click Software Update in the left panel.
  3. Click Install a Software Update in the main panel.
  4. Follow the steps in the wizard to locate and install your PAK file.
  5. Install the product update PAK file.
    Wait for the software update to complete. When it does, the Administrator interface logs you out.
  6. Log back into the primary node Administrator interface.
    The main Cluster Status page appears and cluster goes online automatically. The status page also displays the Bring Online button, but do not click it.
  7. Clear the browser caches and if the browser page does not refresh automatically, refresh the page.
    The cluster status changes to Going Online. When the cluster status changes to Online, the upgrade is complete.

    Note: If a cluster fails and the status changes to offline during the installation process of a PAK file update then some nodes become unavailable. To fix this, you can access the Administrator interface and manually take the cluster offline and click Finish Installation to continue the installation process.
     
  8. Click Software Update to check that the update is done.
    A message indicating that the update completed successfully appears in the main pane.

Once the update is complete delete the snapshots you made before the software update.