SNMP polling for NSX components is limited and may not function as expected
search cancel

SNMP polling for NSX components is limited and may not function as expected

book

Article ID: 371690

calendar_today

Updated On:

Products

VMware NSX

Issue/Introduction

  • SNMP polling for certain NSX components may not function as expected
  • SNMP polling is supported for a limited number of OIDs.

Environment

VMware NSX-T Data Center

VMware NSX

 

Cause

SNMP is supported for use with NSX environments, however there are limitations with SNMP polling of NSX components such as NSX Manager and NSX Edge nodes.

Resolution

SNMP Traps: NSX Manager and Edge Nodes are configured to generate SNMP notifications (traps) to registered SNMP managers whenever alarms are triggered or resolved. NSX MIBs can be found attached to BROADCOM-NSX-MIB

SNMP Polling: NSX SNMP polling is supported in a limited capacity with specific OIDs. This method does not provide comprehensive metrics such as CPU utilization, memory usage, or disk usage for NSX Manager and Edge nodes. The OID's supported for SNMP polling can be determined from the output of the 'snmpwalk' command, example below, ran against the NSX node. NSX MIBs can be found attached to BROADCOM-NSX-MIB

snmpwalk -v2c -c <COMMUNITY-STRING <EDGE-or-MANAGER-IP-ADDRESS>

snmpwalk -v2c -c <COMMUNITY-STRING> -M <PATH-TO-MIBS-FOLDER> <EDGE-or-MANAGER-IP-ADDRESS>

Additional Information

The OIDs supported for polling is changing further in VCF 9 and onwards. See the files attached to this KB for a list of these OIDs from VCF 9 NSX nodes. 

snmpwalk_manager_9_x.txt
snmpwalk_edge_9_x.txt
snmpwalk_manager_9_x_with_mibs.txt
snmpwalk_edge_9_x_with_mibs.txt

Attachments

snmpwalk_manager_9_x_with_mibs.txt get_app
snmpwalk_edge_9_x_with_mibs.txt get_app
snmpwalk_edge_9_x.txt get_app
snmpwalk_manager_9_x.txt get_app