Device gets into automaton but initial deployment fails to run an imaging job.

Environment

8.7.2

Cause

Imported a unsupported version of Windows ADK 10.1.26100.1 (May 2024).

bootwiz.log file shows the following error:

-----------------------------------------------------------------------------------------------------
CBootWizardApp::ExitInstance - Ending application instance
        Exit code: (20) 20 BDC_EXIT_INVALID_OS_TYPE - Invalid OS Type
***************************************************
        Application End
***************************************************

May see other errors as listed in this document: 

https://knowledge.broadcom.com/external/article?articleId=244276

Resolution

From Windows Control Panel > Program and Features uninstall:

  • Windows Assessment and Deployment Kit version 10.1.26200.1 
  • Windows Assessment and Deployment Kit Windows Preinstallation Environment Add-on version 10.1.26200.1 

From Notification Server run through this article: 

Rebuild the preboot configuration