automated_deployment_engine (ade) fails to start and remains in error state (unable to bind to port) due to custom packages
Some fixes were previously included in UIM 23.4 CU1 for this issue
However, this issue was observed to be still intermittently occurring in some environments during upgrade on Primary hub /manual deployment of ade probe on remote hubs having custom packages.
Errors observed:
10032024 14:28:16,886 [main] ERROR ArchiveManager - Scan for packages : Error: <drive>:\<Nimsoft_path>\archive\<custom_package>.zip could not generate ArchiveEntry
com.nimsoft.nimbus.NimException: No value found for key package info/version
at com.nimsoft.nimbus.NimConfig.getValue(NimConfig.java:839) ~[nimsoft-SDK-23.4.0.0.jar:23.4.0.0]
at com.nimsoft.nimbus.NimConfig.getValue(NimConfig.java:695) ~[nimsoft-SDK-23.4.0.0.jar:23.4.0.0]
Defect
The fix that is included in an intermediate CU (CU1.1)
Fixed a crash in the ADE probe that occurred with custom packages having different versions, especially when one version is an integer (e.g., 1, 2, 3) or a blank.
Reference: UIM Server 23.4 - Cumulative Update 1 > Scroll down to UIM Server 23.4 CU1.1