Virtual Machine Nic disconnect with SRM workflow for vMotion.
search cancel

Virtual Machine Nic disconnect with SRM workflow for vMotion.

book

Article ID: 345836

calendar_today

Updated On:

Products

VMware NSX

Issue/Introduction

  • Virtual machine on DR site loses network connectivity when click on the TEST DR tab of the SRM.
  • VM network adapter stays connected in VC. however, the Link is Down in Guest OS.

Environment

VMware NSX-T Data Center
VMware NSX-T Data Center 2.5.2

Cause

NSX 2.5.2 introduced rekeying of vif for SRM but did not cover the case where protected site and recovery site ESXs are in different transport zones.

Resolution

This issue is resolved in VMware NSX 3.0.2, available at Broadcom downloads.

If you are having difficulty finding and downloading software, please review the Download Broadcom products and software KB.

Workaround:
Disconnect the network adapter and reconnecting will fix the issue.

Additional Information

Impact/Risks:
Network connectivity lost for Virtual machine which goes in Nic disconnect.