NSX-T Edge receives a high volume of ARP requests from ESXi Transport Nodes
search cancel

NSX-T Edge receives a high volume of ARP requests from ESXi Transport Nodes

book

Article ID: 318294

calendar_today

Updated On:

Products

VMware NSX VMware NSX-T Data Center

Issue/Introduction

  • NSX-T Data Center 3.1.0 and 3.1.1.
  • The Edge node is receiving a high rate of a ARP Request from the ESXi transport nodes, requesting to resolve 169.254.0.x.
  • On the Edge node, /var/log/syslog has a large number of entries tracking these ARP replies, e.g.
    2021-06-04T18:46:02.359Z Manager1 NSX 6622 SWITCHING [nsx@6876 comp="nsx-edge" subcomp="datapathd" s2comp="arp" level="INFO"] ARP reply sent to 00:50:56:##:##:4a for 169.254.0.2 from 02:50:##:##:53:00 on lrouter port 0c456328-70e5-####-####-########3b1

    2021-06-04T18:46:02.361Z Manager1 NSX 6622 SWITCHING [nsx@6876 comp="nsx-edge" subcomp="datapathd" s2comp="arp" level="INFO"] ARP reply sent to 00:50:56:##:##:4a for 169.254.0.2 from 02:50:##:##:53:00 on lrouter port 0c456328-70e5-####-####-########3b1

    2021-06-04T18:46:02.361Z Manager1 NSX 6622 SWITCHING [nsx@6876 comp="nsx-edge" subcomp="datapathd" s2comp="arp" level="INFO"]  message repeated 2 times: [ARP reply sent to 00:50:##:##:76:4a for 169.254.0.2 from 02:50:##:##:53:00 on lrouter port 0c456328-70e5-####-####-########3b1]
  • If the ARP rate is sufficiently high, the alarm "Edge NIC Out of Receive Buffer" may be triggered on the Edge node.
  • If the ARP rate is sufficiently high, high datapath CPU may be observed against some cores even though the packet rate is not high
    e.g.
    > get dataplane cpu stats

    Core      : 2
    Crypto    : 0 pps
    Intercore : 0 pps
    Kni       : 0 pps
    Rx        : 18460 pps <<
    Slowpath  : 0 pps
    Tx        : 18490 pps
    Usage     : 86%         <<

Environment

VMware NSX-T Data Center

Cause

Incorrect logic in the DR of the ESXi hosts resulted in excessive ARP requests, for the SR/DR IP, being sent on the transit link to the Edge nodes.

Resolution

This issue is resolved in VMware NSX-T Data Center 3.1.2 available at Broadcom Downloads.