Importing Windows ADK for WinPE 11.0 stays on importing:
Information and Errors in the log viewer:
Windows ADK WinPE11 path is:'C:\Program Files (x86)\Windows Kits\10'. Win PE version WinPE11 - x86 BCD install failed. Execution aborted. Error 1. ImportWinPE failed.BDCWinPE install failed. [System.InvalidOperationException @ Symantec.Deployment] at Altiris.Deployment.PrebootEnvironment.WinPeImportTask.ImportADK(String winPeToCreate)
Error executing task 'WinPE11 import task' (c9fe080d-c267-4920-b19c-66c04bb0a1a5).Failure during task execution c9fe080d-c267-4920-b19c-66c04bb0a1a5.
Task execution failed.
[System.InvalidOperationException @ Symantec.Deployment]
at Altiris.Deployment.PrebootEnvironment.PrebootImageCreationSchedule.ExecuteAndWait(Guid taskGuid)
Other similar log messages that you may see are:
Entry 1:Deployment Solution : Windows ADK 11.0 is installed.-----------------------------------------------------------------------------------------------------Date: 9/15/2022 6:13:12 AM, Tick Count: 34832375 (09:40:32.3750000), Size: 327 BProcess: w3wp (5268), Thread ID: 274, Module: Symantec.Deployment.Common.dllPriority: 4, Source: Altiris.Deployment.Common.WinPE11.IsWindowADKInstalled
Entry 2:Deployment Solution: Check command parameter :: -install -q -os WinPE11 -x86 :: -install -q -os WinPE11 -x64 -----------------------------------------------------------------------------------------------------Date: 9/15/2022 6:13:12 AM, Tick Count: 34832437 (09:40:32.4370000), Size: 397 BProcess: w3wp (5268), Thread ID: 274, Module: Symantec.Deployment.Common.dllPriority: 4, Source: Altiris.Deployment.Common.MultipleWinPE.CheckBDCWinPEInstallRunning
Entry 3:Deployment Solution: Attempting WinPE:WinPE11 isBDCWinPEInstalled: false, isWindowADKInstalled: True, checkBDCWinPEInstallRunning: True-----------------------------------------------------------------------------------------------------Date: 9/15/2022 6:13:12 AM, Tick Count: 34832437 (09:40:32.4370000), Size: 357 BProcess: w3wp (5268), Thread ID: 274, Module: w3wp.exePriority: 8, Source: PrebootConfigPolicyPage
Entry 4:ImportADK: Preboot environment version WinPE11 - x86 BCD install failed. Execution aborted. Error 553.-----------------------------------------------------------------------------------------------------Date: 9/15/2022 6:13:13 AM, Tick Count: 34833453 (09:40:33.4530000), Size: 381 BProcess: AeXSvc (1796), Thread ID: 151, Module: Symantec.Deployment.dllPriority: 1, Source: Altiris.Deployment.PrebootEnvironment.WinPeImportTask.ImportAdk
Entry 5:Deployment Solution: ImportADK failed.
BDCWinPE install failed. [System.InvalidOperationException @ Symantec.Deployment] at Altiris.Deployment.PrebootEnvironment.WinPeImportTask.ImportAdk(WinPE peToCreate, String peVersionToCreate, PrebootArcitecture& architecture)
Exception logged from: at Altiris.Deployment.PrebootEnvironment.WinPeImportTask.ImportAdk(Altiris.Deployment.Common.MultipleWinPE+WinPE, String, Altiris.Deployment.PrebootConfiguration+PrebootArcitecture&) at Altiris.Deployment.PrebootEnvironment.WinPeImportTask.ImportWinPe() at Altiris.Deployment.PrebootEnvironment.WinPeImportTask.ExecuteTask(System.Collections.Hashtable, Altiris.NS.ItemTaskManagement.ItemTaskState) at Altiris.NS.TaskManagement.CoreTaskServiceThreadBase<T,TStartArgs>.ExecuteThreadProc(Object) at System.Threading.ExecutionContext.RunInternal(System.Threading.ExecutionContext, System.Threading.ContextCallback, Object, Boolean) at System.Threading.ExecutionContext.Run(System.Threading.ExecutionContext, System.Threading.ContextCallback, Object, Boolean) at System.Threading.ExecutionContext.Run(System.Threading.ExecutionContext, System.Threading.ContextCallback, Object) at System.Threading.ThreadHelper.ThreadStart(Object)
-----------------------------------------------------------------------------------------------------Date: 9/15/2022 6:13:13 AM, Tick Count: 34833453 (09:40:33.4530000), Size: 1.59 KBProcess: AeXSvc (1796), Thread ID: 151, Module: Symantec.Deployment.dllPriority: 1, Source: Altiris.Deployment.PrebootEnvironment.WinPeImportTask.ImportAdk
Entry 6:Error executing task 'WinPE11 import task' (1e67ecd5-2152-419a-bcfa-954278ee488d).-----------------------------------------------------------------------------------------------------Date: 9/15/2022 6:13:13 AM, Tick Count: 34833453 (09:40:33.4530000), Size: 363 BProcess: AeXSvc (1796), Thread ID: 151, Module: Symantec.Deployment.dllPriority: 1, Source: Altiris.Deployment.PrebootEnvironment.WinPeImportTask.ExecuteTask
Entry 7:Operation completed: Executing core task ([00:00:01.4531721] 'WinPE11 import task' (1e67ecd5-2152-419a-bcfa-954278ee488d) (Altiris.Deployment.PrebootEnvironment.WinPeImportTask, id=[1e67ecd5-2152-419a-bcfa-954278ee488d], state=Completed, started=9/15/2022 6:13:12 AM, finished=9/15/2022 6:13:13 AM)), total time=00:00:01.4432032-----------------------------------------------------------------------------------------------------Date: 9/15/2022 6:13:13 AM, Tick Count: 34833468 (09:40:33.4680000), Size: 553 BProcess: AeXSvc (1796), Thread ID: 151, Module: AeXSVC.exePriority: 16, Source: CoreTaskServiceThread
Entry 8:Failure during task execution 1e67ecd5-2152-419a-bcfa-954278ee488d.
Task execution failed. [System.InvalidOperationException @ Symantec.Deployment] at Altiris.Deployment.PrebootEnvironment.PrebootImageCreationSchedule.ExecuteAndWait(Guid taskGuid)
Exception logged from: at Altiris.Deployment.PrebootEnvironment.PrebootImageCreationSchedule.ExecuteAndWait(System.Guid) at Altiris.Deployment.PrebootEnvironment.PrebootImageCreationSchedule.ExecuteWinPEImagingTask() at Altiris.Deployment.PrebootEnvironment.PrebootImageCreationSchedule.ExecuteWinPEImagingTasks() at Altiris.Deployment.PrebootEnvironment.PrebootImageCreationSchedule.OnSchedule(String) at Altiris.NS.Scheduling.ScheduleService.ProcessScheduleImpl(String, Altiris.Profiling.CodeProfiling.CodeProfiler, Altiris.NS.Security.SecurityContext, System.Guid) at Altiris.NS.Scheduling.ScheduleService+<>c_DisplayClass0_0.<ProcessSchedule>b_0(Altiris.NS.Security.SecurityContext) at Altiris.NS.Security.SecurityContext+<>c_DisplayClass46_0.<ExecuteAsOwner>b_1(Altiris.NS.Security.SecurityContext) at Altiris.NS.Security.SecurityContext.ExecuteAs<T,TK>(Altiris.NS.Security.EExecuteAs, TK, System.Func<TK,Altiris.NS.Security.SecurityContext>, System.Func<Altiris.NS.Security.SecurityContext,T>) at Altiris.NS.Scheduling.ScheduleService.ProcessSchedule(String) at System.Runtime.Remoting.Messaging.StackBuilderSink._PrivateProcessMessage(IntPtr, Object[], Object, Object[]&) at System.Runtime.Remoting.Messaging.StackBuilderSink.SyncProcessMessage(System.Runtime.Remoting.Messaging.IMessage) at System.Runtime.Remoting.Messaging.ServerObjectTerminatorSink.SyncProcessMessage(System.Runtime.Remoting.Messaging.IMessage) at System.Runtime.Remoting.Messaging.ServerContextTerminatorSink.SyncProcessMessage(System.Runtime.Remoting.Messaging.IMessage) at System.Runtime.Remoting.Channels.CrossContextChannel.SyncProcessMessageCallback(Object[]) at System.Runtime.Remoting.Channels.ChannelServices.DispatchMessage(System.Runtime.Remoting.Channels.IServerChannelSinkStack, System.Runtime.Remoting.Messaging.IMessage, System.Runtime.Remoting.Messaging.IMessage&) at System.Runtime.Remoting.Channels.BinaryServerFormatterSink.ProcessMessage(System.Runtime.Remoting.Channels.IServerChannelSinkStack, System.Runtime.Remoting.Messaging.IMessage, System.Runtime.Remoting.Channels.ITransportHeaders, System.IO.Stream, System.Runtime.Remoting.Messaging.IMessage&, System.Runtime.Remoting.Channels.ITransportHeaders&, System.IO.Stream&) at System.Runtime.Remoting.Channels.SoapServerFormatterSink.ProcessMessage(System.Runtime.Remoting.Channels.IServerChannelSinkStack, System.Runtime.Remoting.Messaging.IMessage, System.Runtime.Remoting.Channels.ITransportHeaders, System.IO.Stream, System.Runtime.Remoting.Messaging.IMessage&, System.Runtime.Remoting.Channels.ITransportHeaders&, System.IO.Stream&) at System.Runtime.Remoting.MetadataServices.SdlChannelSink.ProcessMessage(System.Runtime.Remoting.Channels.IServerChannelSinkStack, System.Runtime.Remoting.Messaging.IMessage, System.Runtime.Remoting.Channels.ITransportHeaders, System.IO.Stream, System.Runtime.Remoting.Messaging.IMessage&, System.Runtime.Remoting.Channels.ITransportHeaders&, System.IO.Stream&) at System.Runtime.Remoting.Channels.Tcp.TcpServerTransportSink.ServiceRequest(Object) at System.Runtime.Remoting.Channels.SocketHandler.ProcessRequestNow() at System.Runtime.Remoting.Channels.SocketHandler.BeginReadMessageCallback(IAsyncResult) at System.Net.LazyAsyncResult.Complete(IntPtr) at System.Threading.ExecutionContext.RunInternal(System.Threading.ExecutionContext, System.Threading.ContextCallback, Object, Boolean) at System.Threading.ExecutionContext.Run(System.Threading.ExecutionContext, System.Threading.ContextCallback, Object, Boolean) at System.Threading.ExecutionContext.Run(System.Threading.ExecutionContext, System.Threading.ContextCallback, Object) at System.Net.ContextAwareResult.Complete(IntPtr) at System.Net.LazyAsyncResult.ProtectedInvokeCallback(Object, IntPtr) at System.Net.Sockets.BaseOverlappedAsyncResult.CompletionPortCallback(UInt32, UInt32, System.Threading.NativeOverlapped*) at System.Threading._IOCompletionCallback.PerformIOCompletionCallback(UInt32, UInt32, System.Threading.NativeOverlapped*)
-----------------------------------------------------------------------------------------------------Date: 9/15/2022 6:13:14 AM, Tick Count: 34834046 (09:40:34.0460000), Size: 4.59 KBProcess: AeXSvc (1796), Thread ID: 100, Module: Symantec.Deployment.dllPriority: 1, Source: PrebootImageCreationSchedule
Entry 9:WinPE build completed.-----------------------------------------------------------------------------------------------------Date: 9/15/2022 6:13:14 AM, Tick Count: 34834062 (09:40:34.0620000), Size: 253 BProcess: AeXSvc (1796), Thread ID: 100, Module: AeXSVC.exePriority: 4, Source: PrebootImageCreationSchedule
Entry 10:Bootwiz log error-----------------------------------------------------------------------------------------------------CBootWizardApp::ExitInstance - Ending application instance Exit code: (20) 20 BDC_EXIT_INVALID_OS_TYPE - Invalid OS Type*************************************************** Application End***************************************************
ITMS 8.x
DS 8.x
Windows 11 is not available in a 32-bit architecture, so the 32-bit version of Windows PE for Windows 11 is not supported; and Deployment solution looks for WindowsPE x86 which does not exist in the Windows kits folder.
Support for the WinPE 11 is available in ITMS 8.6 RU1 and WINPE 11 22H2 is supported in ITMS 8.7 per the Deployment Solution OS Support Matrix and Client OS Support Matrix.
Workaround 1:
Workaround 2: