The older r630/r730 Security Analytics (Solera) appliances come in one of two main configurations. Stand-a-lone appliances and a head unit with one or more external storage enclosures. The goal of this article is to help you identify if you have a problem, and if so, what sort of information should you gather before contacting Technical Support.
The newer systems use storage arrays. They either use Netapp E5660 or U144/U084, also known as Dell ME4. These units use a different architecture. See
https://knowledge.broadcom.com/external/article/238767/update-me4-storage-array-controllers-and.html
Some other symptoms you may experience if there are possible hard drive issues:
Due to the fact that the Security Analytics appliances have a redundant RAID configuration (RAID 1 and RAID 5), you can often have a drive fail without losing functionality. If a drive does fail, you may get a syslog or email alert depending on how you have configured the communication logging settings. If you think you have an error, use the following methods to confirm:
1. Use the Audit Log
From within the GUI, go to Settings and then Audit Log. To filter down just the Hardware messages, in the Advanced Filter section, enter "category=Hardware Events" and you should just see the Hardware related issues. Search for "Failure" or "Degraded" or "Failed" or "Predictive". If you find these messages, support will need the full output of the error. Below is an example:
Adapter 0; seqNum: 0x0000603e; Time: Sat Nov 22 03:18:24 2014; Event Description: Predictive failure: PD 06(e0x20/s6); Device ID: 6; Enclosure Index: 32; Slot Number: 6;
2. Use 'lsi-show' to determine which HDD has failed.
The command 'lsi-show' is useful in that it queries the raid controllers and will provide a detailed listing of all physical and logical units regardless of the current hardware state. A sample lsi-show output can be found in the "Additional Information" section below. If everything is healthy, you will see all Logical Drives in an "Optimal" status and all Physical Drives will show as "Online". If a drive has failed, it will show up in this report. Be aware that lsi-show will not provide hard drive information for large storage arrays such as the Dell MD3860 or the NetApp E5600 or the Dell Seagate storage arrays.
NOTE: if you don't have a root access from the CLI, you can SSH as the 'admin' user and use the 'sudo lsi-show' command. The lsi-show.txt file is also part of the CSR (generated by going to Settings > System -> Download CSR. This may take 5-15 minutes and be from 100MB to 1GB+ in size.
lsi-show includes the following -
For example -
Controller Information
Id Serial No Firmware Encl LD PD Product Name
a0 SERIAL_NUMBER 4.270.00-8168 1 2 26 PERC H730P Mini
Enclosure Information
Id Drives
32 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
Logical Drive Information
Id Size Status Stripe Raid Level Cache
0 5.456 TB Optimal 64 KB Primary-5 WriteBack, ReadAhead, Direct, Write Cache OK if Bad BBU
by id: 22,23,24,25
by es: 32:22,32:23,32:24,32:25
1 34.557 TB Optimal 64 KB Primary-5 WriteBack, ReadAhead, Direct, Write Cache OK if Bad BBU
by id: 0,1,2,3,4,5,6,7,8,9,10,11,12,13,14,15,16,17,18,19
by es: 32:0,32:1,32:2,32:3,32:4,32:5,32:6,32:7,32:8,32:9,32:10,32:11,32:12,32:13,32:14,32:15,32:16,32:17,32:18,32:19
Physical Drive Information
Id E:S Status FC Size Inquiry
0 32:0 Online, Spun Up None 1.819 TB SEAGATE ST2000NX0453 SERIAL_NUMBER
1 32:1 Online, Spun Up None 1.819 TB SEAGATE ST2000NX0453 SERIAL_NUMBER
2 32:2 Online, Spun Up None 1.819 TB SEAGATE ST2000NX0453 SERIAL_NUMBER
3 32:3 Online, Spun Up None 1.819 TB SEAGATE ST2000NX0453 SERIAL_NUMBER
4 32:4 Online, Spun Up None 1.819 TB SEAGATE ST2000NX0453 SERIAL_NUMBER
5 32:5 Online, Spun Up None 1.819 TB SEAGATE ST2000NX0453 SERIAL_NUMBER
6 32:6 Online, Spun Up None 1.819 TB SEAGATE ST2000NX0453 SERIAL_NUMBER
7 32:7 Online, Spun Up None 1.819 TB SEAGATE ST2000NX0453 SERIAL_NUMBER
8 32:8 Online, Spun Up None 1.819 TB SEAGATE ST2000NX0453 SERIAL_NUMBER
9 32:9 Online, Spun Up None 1.819 TB SEAGATE ST2000NX0453 SERIAL_NUMBER
10 32:10 Online, Spun Up None 1.819 TB SEAGATE ST2000NX0453 SERIAL_NUMBER
11 32:11 Online, Spun Up None 1.819 TB SEAGATE ST2000NX0453 SERIAL_NUMBER
12 32:12 Online, Spun Up None 1.819 TB SEAGATE ST2000NX0453 SERIAL_NUMBER
13 32:13 Online, Spun Up None 1.819 TB SEAGATE ST2000NX0453 SERIAL_NUMBER
14 32:14 Online, Spun Up None 1.819 TB SEAGATE ST2000NX0453 SERIAL_NUMBER
15 32:15 Online, Spun Up None 1.819 TB SEAGATE ST2000NX0453 SERIAL_NUMBER
16 32:16 Online, Spun Up None 1.819 TB SEAGATE ST2000NX0453 SERIAL_NUMBER
17 32:17 Online, Spun Up None 1.819 TB SEAGATE ST2000NX0453 SERIAL_NUMBER
18 32:18 Online, Spun Up None 1.819 TB SEAGATE ST2000NX0453 SERIAL_NUMBER
19 32:19 Online, Spun Up None 1.819 TB SEAGATE ST2000NX0453 SERIAL_NUMBER
20 32:20 Unconfigured(good), Spun Up None 1.819 TB SEAGATE ST2000NX0453 SERIAL_NUMBER
21 32:21 Unconfigured(good), Spun Up None 1.819 TB SEAGATE ST2000NX0453 SERIAL_NUMBER
22 32:22 Online, Spun Up None 1.819 TB SEAGATE ST2000NX0453 SERIAL_NUMBER
23 32:23 Online, Spun Up None 1.819 TB SEAGATE ST2000NX0453 SERIAL_NUMBER
24 32:24 Online, Spun Up None 1.819 TB SEAGATE ST2000NX0453 SERIAL_NUMBER
25 32:25 Online, Spun Up None 1.819 TB SEAGATE ST2000NX0453 SERIAL_NUMBER
Controller Information
Id Serial No Firmware Encl LD PD Product Name
a1 SERIAL_NUMBER 4.270.00-8168 2 2 24 PERC H830 Adapter
Enclosure Information
Id Drives
0 1 4 5 2 7 9 8 11 10 12 3 6
13 17 18 16 15 23 21 20 19 24 25 14 22
Logical Drive Information
Id Size Status Stripe Raid Level Cache
0 40.019 TB Optimal 64 KB Primary-5 WriteBack, ReadAhead, Direct, Write Cache OK if Bad BBU
by id: 1,4,5,2,7,9,8,11,10,12,3,6
by es: 0:1,0:2,0:3,0:4,0:5,0:6,0:7,0:8,0:9,0:10,0:11,0:12
1 40.019 TB Optimal 64 KB Primary-5 WriteBack, ReadAhead, Direct, Write Cache OK if Bad BBU
by id: 17,18,16,15,23,21,20,19,24,25,14,22
by es: 13:1,13:2,13:3,13:4,13:5,13:6,13:7,13:8,13:9,13:10,13:11,13:12
Physical Drive Information
Id E:S Status FC Size Inquiry
1 0:1 Online, Spun Up None 3.638 TB HGST HUS726040AL5215 SERIAL_NUMBER
4 0:2 Online, Spun Up None 3.638 TB HGST HUS726040AL5215 SERIAL_NUMBER
5 0:3 Online, Spun Up None 3.638 TB HGST HUS726040AL5215 SERIAL_NUMBER
2 0:4 Online, Spun Up None 3.638 TB HGST HUS726040AL5215 SERIAL_NUMBER
7 0:5 Online, Spun Up None 3.638 TB HGST HUS726040AL5215 SERIAL_NUMBER
9 0:6 Online, Spun Up None 3.638 TB HGST HUS726040AL5215 SERIAL_NUMBER
8 0:7 Online, Spun Up None 3.638 TB HGST HUS726040AL5215 SERIAL_NUMBER
11 0:8 Online, Spun Up None 3.638 TB HGST HUS726040AL5215 SERIAL_NUMBER
10 0:9 Online, Spun Up None 3.638 TB HGST HUS726040AL5215 SERIAL_NUMBER
12 0:10 Online, Spun Up None 3.638 TB HGST HUS726040AL5215 SERIAL_NUMBER
3 0:11 Online, Spun Up None 3.638 TB HGST HUS726040AL5215 SERIAL_NUMBER
6 0:12 Online, Spun Up None 3.638 TB HGST HUS726040AL5215 SERIAL_NUMBER
17 13:1 Online, Spun Up None 3.638 TB HGST HUS726040AL5215 SERIAL_NUMBER
18 13:2 Online, Spun Up None 3.638 TB HGST HUS726040AL5215 SERIAL_NUMBER
16 13:3 Online, Spun Up None 3.638 TB HGST HUS726040AL5215 SERIAL_NUMBER
15 13:4 Online, Spun Up None 3.638 TB HGST HUS726040AL5215 SERIAL_NUMBER
23 13:5 Online, Spun Up None 3.638 TB HGST HUS726040AL5215 SERIAL_NUMBER
21 13:6 Online, Spun Up None 3.638 TB HGST HUS726040AL5215 SERIAL_NUMBER
20 13:7 Online, Spun Up None 3.638 TB HGST HUS726040AL5215 SERIAL_NUMBER
19 13:8 Online, Spun Up None 3.638 TB HGST HUS726040AL5215 SERIAL_NUMBER
24 13:9 Online, Spun Up None 3.638 TB HGST HUS726040AL5215 SERIAL_NUMBER
25 13:10 Online, Spun Up None 3.638 TB HGST HUS726040AL5215 SERIAL_NUMBER
14 13:11 Online, Spun Up None 3.638 TB HGST HUS726040AL5215 SERIAL_NUMBER
22 13:12 Online, Spun Up None 3.638 TB HGST HUS726040AL5215 SERIAL_NUMBER
Controller Information
Id Serial No Firmware Encl LD PD Product Name
a2 SERIAL_NUMBER 4.270.00-8168 2 2 24 PERC H830 Adapter
Enclosure Information
Id Drives
0 1 2 4 5 7 8 9 10 11 12 3 6
13 15 14 17 18 23 22 16 19 24 20 21 25
Logical Drive Information
Id Size Status Stripe Raid Level Cache
0 40.019 TB Offline 64 KB Primary-5 WriteThrough, ReadAheadNone, Direct, Write Cache OK if Bad BBU
by id: 1,2,4,5,7,8,9,10,11,12,3,6
by es: 0:1,0:2,0:3,0:4,0:5,0:6,0:7,0:8,0:9,0:10,0:11,0:12
1 40.019 TB Optimal 64 KB Primary-5 WriteThrough, ReadAheadNone, Direct, Write Cache OK if Bad BBU
by id: 15,14,17,18,23,22,16,19,24,20,21,25
by es: 13:1,13:2,13:3,13:4,13:5,13:6,13:7,13:8,13:9,13:10,13:11,13:12
Physical Drive Information
Id E:S Status FC Size Inquiry
1 0:1 Failed None 3.638 TB HGST HUS726040AL5215 SERIAL_NUMBER
2 0:2 Failed None 3.638 TB HGST HUS726040AL5215 SERIAL_NUMBER
4 0:3 Failed None 3.638 TB HGST HUS726040AL5215 SERIAL_NUMBER
5 0:4 Failed None 3.638 TB HGST HUS726040AL5215 SERIAL_NUMBER
7 0:5 Failed None 3.638 TB HGST HUS726040AL5215 SERIAL_NUMBER
8 0:6 Failed None 3.638 TB HGST HUS726040AL5215 SERIAL_NUMBER
9 0:7 Failed None 3.638 TB HGST HUS726040AL5215 SERIAL_NUMBER
10 0:8 Failed None 3.638 TB HGST HUS726040AL5215 SERIAL_NUMBER
11 0:9 Failed None 3.638 TB HGST HUS726040AL5215 SERIAL_NUMBER
12 0:10 Failed None 3.638 TB HGST HUS726040AL5215 SERIAL_NUMBER
3 0:11 Failed None 3.638 TB HGST HUS726040AL5215 SERIAL_NUMBER
6 0:12 Failed None 3.638 TB HGST HUS726040AL5215 SERIAL_NUMBER
15 13:1 Online, Spun Up None 3.638 TB HGST HUS726040AL5215 SERIAL_NUMBER
14 13:2 Online, Spun Up None 3.638 TB HGST HUS726040AL5215 SERIAL_NUMBER
17 13:3 Online, Spun Up None 3.638 TB HGST HUS726040AL5215 SERIAL_NUMBER
18 13:4 Online, Spun Up None 3.638 TB HGST HUS726040AL5215 SERIAL_NUMBER
23 13:5 Online, Spun Up None 3.638 TB HGST HUS726040AL5215 SERIAL_NUMBER
22 13:6 Online, Spun Up None 3.638 TB HGST HUS726040AL5215 SERIAL_NUMBER
16 13:7 Online, Spun Up None 3.638 TB HGST HUS726040AL5215 SERIAL_NUMBER
19 13:8 Online, Spun Up None 3.638 TB HGST HUS726040AL5215 SERIAL_NUMBER
24 13:9 Online, Spun Up None 3.638 TB HGST HUS726040AL5215 SERIAL_NUMBER
20 13:10 Online, Spun Up None 3.638 TB HGST HUS726040AL5215 SERIAL_NUMBER
21 13:11 Online, Spun Up None 3.638 TB HGST HUS726040AL5215 SERIAL_NUMBER
25 13:12 Online, Spun Up None 3.638 TB HGST HUS726040AL5215 SERIAL_NUMBER
A few example of drive status:
The drive is not being used and is not spinning.
37 35:2 Unconfigured(good), Spun down None 3.638 TB HGST HUS726T4TAL5205 SERIAL_NUMBER
The drive is not being used and is spinning -
20 32:20 Unconfigured(good), Spun Up None 1.819 TB SEAGATE ST2000NX0453 SERIAL_NUMBER
The virtual disk has a failed component -
0 931.0 GB Degraded 64 KB Primary-1 WriteBack, ReadAdaptive, Direct, Write Cache OK if Bad BBU
One virtual disk has failed and is not functional. It likely has two drives which have failed.
2 4.545 TB Offline 64 KB Primary-5 WriteBack, ReadAdaptive, Direct, Write Cache OK if Bad BBU
This drive is still recognized but has failed -
1 0:1 Failed None 3.638 TB HGST HUS726040AL5215 SERIAL_NUMBER
The drive has been detached and re-attached. All drives on this controller will need to be imported by controller number. For example, megacli -cfgforeign -import -a1
74 77:0 Unconfigured(good), Spun Up Foreign 3.638 TB TOSHIBA MG04SCA40EN SERIAL_NUMBER
Be prepared with the lsi-show output and any pertinent audit log messages before calling technical support to submit an RMA for a replacement drive. If you have Dell hardware, we will also need the Dell Service Tag, which can be located on the physical appliance itself or by running the following command from the CLI as the root user: dmidecode -s system-serial-number.
If the failed drive happens to be in one of the Dell external attached storage devices, we will need the Service Tag from the storage enclosure. The serial number for all enclosures can be obtained with:
megacli -encinfo -aall | egrep "adapter|Device ID|Physical|Vendor Specific"
When opening a new case, be sure to include the shipping address with contact name and phone number. Also, we will need to know if you will replace the drive yourselves or do you want a field tech to do the work.