How To re-download and install WinPE10 in Deployment Solution 8.0/8.1

book

Article ID: 165085

calendar_today

Updated On:

Products

Deployment Solution

Issue/Introduction

Need to re-download and install WinPE (Windows PE) in DS (Deployment Solution) 8.0/8.1.

Cause

Corrupted WinPE install.

Environment

DS 8.0.x/8.1.x.

Resolution

‚ÄčTo regenerate the WinPE in bootwiz follow the below steps:

  1. Locate the PreBootOs.ini on the NS server at "\Program Files\Altiris\Deployment\BDC\bootwiz\".
  2. Navigate to line [WINPE10_X64] and modify line INSTALLED=True to False.
  3. This will cause the system to think the ADK has not been installed yet.
  4. Save PreBootOs.ini and restart the SMP (Symantec Management Platform) console (browser).
  5. Access the pre-boot configuration window (Settings -> Deployment -> create pre-boot configuration).
  6. Follow the instructions on the screen on how to download and install the Windows ADK.