ESXi host with BCM5750x NICs have BFD tunnels down in an NSX environment
search cancel

ESXi host with BCM5750x NICs have BFD tunnels down in an NSX environment

book

Article ID: 317924

calendar_today

Updated On:

Products

VMware NSX VMware vSphere ESXi

Issue/Introduction

  • ESXi Host TEP tunnels are down or intermittently down.
  • Impacted hosts are not receiving BFD packets from the tunnel peer.
  • Run the following command from an ESXi root shell. In the output for the tunnel experiencing the issue, the "recv" counter does not increment:
    nsxdp-cli bfd sessions list
  • Host NICs are Broadcom BCM5750x running bnxtnet driver:
    • VID 0x14e4 DID 0x1750 NetXtreme-E P2100D BCM57508 2x100G QSFP PCIE Ethernet
    • VID 0x14e4 DID 0x1751 NetXtreme E-Series Quad-port 25Gb OCP 3.0 Ethernet Adapter
  • NIC firmware versions 220.xx, 221.xx, 222.xx, and 223.xx.

Environment

  • VMware NSX-T Data Center
  • VMware NSX
  • VMware ESXi

Cause

This is a known issue with Broadcom BCM5750x NIC handling of BFD packets.

Resolution

This issue has been resolved in the following drivers :

ESXi 8.*/9.x  - 223.0.206.0 & later
ESXI 7.*  - 223.0.152.2 & later