出现了常规系统错误:在 PreCloneCheckCallback 过程中出现 PBM 错误: vmodl.fault.systemerror ( A general system error occurred: PBM error occurred during PreCloneCheckCallback: vmodl.fault.systemerror)
注意:在 vCenter Server Appliance 中,此日志位于 /var/log/vmware/vpxd/vpxd.log 文件中。
<YYYY-MM-DD>T<time> warning vpxd[7F22254CB700] [Originator@6876 sub=Default] Failed to connect socket; <io_obj p:0x00007f223e0fff00, h:21, <TCP '0.0.0.0:0'>, <TCP '127.0.0.1:8190'>>, e: system:111(Connection refused)</time><YYYY-MM-DD>T<time> warning vpxd[7F222503A700] [Originator@6876 sub=Default] Failed to connect socket; <io_obj p:0x00007f223f354be0, h:21, <TCP '0.0.0.0:0'>, <TCP '10.27.45.75:8190'>>, e: system:111(Connection refused)</time><YYYY-MM-DD>T<time> error vpxd[7F222503A700] [Originator@6876 sub=HttpConnectionPool-000057] [ConnectComplete] Connect failed to <cs p:00007f221d44ffa0, TCP:localhost:8190>; cnx: (null), error: N7Vmacore15SystemExceptionE(Connection refused)</time><YYYY-MM-DD>T<time> info vpxd[7F2224BD8700] [Originator@6876 sub=pbm opID=FE46CD39-0000065A-e1-5] PBMCallback: HasUserDefinedPolicies: PBM error occurred during QueryProfile: Connection refused</time><YYYY-MM-DD>T<time> info vpxd[7F2224BD8700] [Originator@6876 sub=pbm opID=FE46CD39-0000065A-e1-5] PBMCallback: ~PbmFunctionTracer: Leaving HasUserDefinedPolicies</time><YYYY-MM-DD>T<time> error vpxd[7F2224BD8700] [Originator@6876 sub=pbm opID=FE46CD39-0000065A-e1-5] PBMCallback: HandleInternalFaultMessage: PBM error occurred during PreCloneCheckCallback: vmodl.fault.SystemError</time><YYYY-MM-DD>T<time> info vpxd[7F2224BD8700] [Originator@6876 sub=pbm opID=FE46CD39-0000065A-e1-5] PBMCallback: ~PbmFunctionTracer: Leaving PreCloneCheckCallback</time><YYYY-MM-DD>T<time> error vpxd[7F2224BD8700] [Originator@6876 sub=VmProv opID=FE46CD39-0000065A-e1-5] [CallbackManager] Got exception while invoking precheck on PbmCallBack: vmodl.fault.SystemError</time>-->--> [backtrace begin] product: VMware VirtualCenter, version: 6.0.0, build: build-2559267, tag: vpxd--> backtrace[00] libvmacore.so[0x003C0094]: Vmacore::System::Stacktrace::CaptureWork(unsigned int)--> backtrace[01] libvmacore.so[0x001EDBA3]: Vmacore::System::SystemFactoryImpl::CreateQuickBacktrace(Vmacore::Ref<Vmacore::System::Backtrace>&)--> backtrace[02] libvmacore.so[0x001988AD]: Vmacore::Throwable::Throwable(std::string const&)--> backtrace[03] vpxd[0x00BD070E]: Vmomi::Fault::SystemError::Exception::Exception(std::string const&)--> backtrace[04] vpxd[0x01799FAA]: PbmService::HandleInternalFaultMessage(Vmacore::Exception*, std::string const&, Vpx::Vmprov::Context*) const--> backtrace[05] vpxd[0x01792D63]--> backtrace[06] vpxd[0x01CDD99B]--> backtrace[07] vpxd[0x01D47F16]--> backtrace[08] vpxd[0x01D5E00D]
要解决此问题,请确保 Profile-Driven Storage Service 正在运行。
对于 vCenter Server Appliance,请执行以下操作: