/var/run/log/vobd.log :
2026-06-24T16:07:25.269Z In(14) vobd[2097812]: [netCorrelator] 2820463594545us: [vob.net.vmnic.linkstate.up] vmnic vmnic0 link state up
/var/run/log/vmkernel.log :
2026-06-24T16:03:43.346Z In(182) vmkernel: cpu58:2098699)CMMDS: CMMDSAgentlikeCheckNode:3119: 52######-80##-28##-66##-d4##########: Lost contact with leader.
/var/run/log/vsansystem.log :
2026-06-24T16:03:47.660Z In(166) vsansystem[2100167]: [vSAN@6876 sub=VsanSystemProvider opId=CMMDSMembershipUpdate-d4e7] Complete, nodeCount: 1, runtime info: (vim.vsan.host.VsanRuntimeInfo) {
VMware vSAN 8.x
DVSwitch: vSAN-Cluster-Test Flags: S - Device is sending Slow LACPDUs, F - Device is sending fast LACPDUs, A - Device is in active mode, P - Device is in passive mode LAG ID: 1####### Mode: Active Nic List: Local Information: Admin Key: 15 Flags: SA Oper Key: 1# Port Number: 2 Port Priority: 255 Port State: ACT,AGG,SYN,COL,DIST, Nic: vmnic1 Partner Information: Age: 00:00:02 Device ID: 0#:2#:0#:e#:b#:7# Flags: SA Oper Key: 3#### Port Number: 16677 Port Priority: 32768 Port State: ACT,AGG,SYN,COL,DIST, State: Bundled
Local Information: Admin Key: 15 Flags: SA Oper Key: 1# Port Number: 1 Port Priority: 255 Port State: ACT,AGG,SYN,COL,DIST, Nic: vmnic0 Partner Information: Age: 00:00:18 Device ID: 0#:2#:0#:e#:b#:7# Flags: SA Oper Key: 33### Port Number: 293 Port Priority: 32768 Port State: ACT,AGG,SYN,COL,DIST, State: Bundled
To resolve this issue, LACP convergence must be optimized to occur faster than the vSAN isolation threshold.