Following upgrade/deployment of ESXi hosts 8.0U3 vcls vms appear but do not power on,
vcls vm's show as in a powered of state with all options greyed out.
In the UI you see the vcls vm cycle from appearing on the host to disappearing.
By checking the infravisor.log located at /var/run/log/infravisor.log on the ESXi host you see the following error:
0000-00-00T00:00:00Z No(5) infravisor[7488117]: time="0000-00-00T00:00:00Z" level=error msg="unexpected fault: &{{{{<nil> [{{} msg.featurecompat.requirement.number.mismatch [{{} 1 cpuid.mwait} {{} 2 0} {{} 3 1}] Feature 'cpuid.mwait' was 0, but must be 1.} {{} msg.moduletable.powerOnFailed [{{} 1 FeatureCompatLate}] Module 'FeatureCompatLate' power on failed. } {{} msg.vmx.poweron.failed [] Failed to start the virtual machine.}]}}} Feature 'cpuid.mwait' was 0, but must be 1.} taskerror: Feature 'cpuid.mwait' was 0, but must be 1." VM-OP=PowerOn namespace=vcls pod=vcls-********-****-****-****-************ uid=***
ESXi 8.0U3
Missing mwait feature on physical host bios.
Please enable cpu mwait feature on the server.
For more information see:
https://knowledge.broadcom.com/external/article/390674/vcls-vms-unable-to-power-on-with-no-host.html