Aria Automation (Version 8.18.x) is experiencing intermittent startup failures, specifically generating error code LCMVRAVACONFIG590070.
Aria Automation 8.18.x
The intermittent startup failure is caused by a timing conflict during the power-on process of Aria Automation.
When this issue happened, following message can be seen in both deploy.log(Aria Automation) and vmware_vrlcm.log(Aria Suite Lifecycle):
+ vracli cluster exec -- bash -c /opt/scripts/set_permissions_and_ownership.py
executing bash on command-executor-q7xxz failed: error: Internal error occurred: error sending request: Post "https:<IP Address>?command=run-on-execd&command=--&command=bash&command=-c&command=/opt/scripts/set_permissions_and_ownership.py&error=1&output=1": dial tcp <IP Address>:10250: connect: connection refused
Currently, there is no permanent fix or patch available for this issue. The recommended workaround is to perform a manual restart of Aria Automation when this issue happens.