Sep 12 11:28:47 VM-NAME kernel: JBD2: Detected IO errors while flushing file data on dm-2-8
Sep 12 11:28:49 VM-NAME kernel: JBD2: Detected IO errors while flushing file data on dm-2-8
Sep 12 11:28:52 VM-NAME kernel: JBD2: Detected IO errors while flushing file data on dm-2-8
2024-09-12T08:28:45.745Z In(182) vmkernel: cpu52:136841550)Fil6: 4179: 'DATASTORE-NAME': Fil6 file IO (<FD c60 r110>) : Limit exceeded
2024-09-12T08:28:45.746Z In(182) vmkernel: cpu60:147041128)Fil6: 4179: 'DATASTORE-NAME': Fil6 file IO (<FD c60 r110>) : Limit exceeded
2024-09-12T08:28:45.747Z In(182) vmkernel: cpu48:147071119)Fil6: 4179: 'DATASTORE-NAME': Fil6 file IO (<FD c60 r110>) : Limit exceeded
2024-09-12T08:28:45.747Z In(182) vmkernel: cpu82:147041126)Fil6: 4179: 'DATASTORE-NAME': Fil6 file IO (<FD c60 r110>) : Limit exceeded
2024-09-12T08:28:45.750Z In(182) vmkernel: cpu3:147041137)Fil6: 4179: 'DATASTORE-NAME': Fil6 file IO (<FD c60 r110>) : Limit exceeded
2024-09-12T08:28:45.751Z In(182) vmkernel: cpu79:147041125)Fil6: 4179: 'DATASTORE-NAME': Fil6 file IO (<FD c60 r110>) : Limit exceeded
2024-09-12T08:28:45.752Z In(182) vmkernel: cpu55:146964280)Fil6: 4179: 'DATASTORE-NAME': Fil6 file IO (<FD c60 r110>) : Limit exceeded
VMware vSphere 7.0.x
VMware vSphere 8.0.x
The datastore where the VM's files reside was expanded, but not all ESXi hosts that are connected to it were refreshed with the new information and are not aware of the new size of the datastore. So the VM tries to send IO operations to a block that the host believes is outside the datastore, causing the issues seen.
In other words, if a storge rescan is not run, or if it fails on a host, then, when that host next queries the volume metadata it will find a mismatch between the extended volume size recorded and its cached record of the original smaller device size.
Perform a storage rescan on all hosts that are connected to this datastore, to have the new size information refreshed in all of them.