Edge node stops forwarding all traffic
book
Article ID: 324170
calendar_today
Updated On:
Products
VMware NSX
Issue/Introduction
- NSX all versions
- Edge datapath stops functioning as expected and stops forwarding traffic
- NSX Edge syslog has a log signature similar to this example
2024-02-24T13:37:03.663Z Edge 07b7117dfd5a 3774 - - 2024-02-24T13:37:03Z datapathd 16336 epconn-services tname="dp-ipc31" [ERROR] Failed to operate: Processing request from NSXA (-22) errorCode="EDG0000005"
2024-02-24T13:37:03.221Z Edge datapath-systemd-helper 16235 - - 2024-02-24T13:37:03Z datapathd 16336 epconn-services tname="dp-ipc31" [ERROR] Failed to operate: Processing request from NSXA (-22) errorCode="EDG0000005"
Cause
In very rare cases, the Edge may stop forwarding traffic due to epconn connection getting closed to NSXA.
Resolution
This issue is resolved in VMware NSX 4.2.0
Workaround:
Reboot the impacted Edge.
Feedback
thumb_up
Yes
thumb_down
No