Some database objects show as Invalid in Health Report
search cancel

Some database objects show as Invalid in Health Report

book

Article ID: 9200

calendar_today

Updated On:

Products

Clarity PPM On Premise Clarity PPM SaaS

Issue/Introduction

Going in the Health Report link that can be accessed from the Administration Menu.

There are red X icons showing issues with the database. Is this of concern?

This Health Report provides information about invalid objects in both PPM schema and the Data Warehouse schema. And can report a variable number of database objects as being invalid.

Environment

Release: All Supported Releases

Resolution

  • There is typically no need to take any steps to validate these objects specifically, unless unexpected behavior is being noticed in application functionality
  • Some invalid objects are compiled at runtime (upon access)
  • To specifically look into persistent invalid objects, work with your DBA to provide you a list of invalid object name and the object type and follow Invalid objects on the database instance

Note: There will always be 3 objects that are invalid as they are used when the Oracle database is imported/refreshed, however it will not cause any issues with Clarity operation.

SYS_PLSQL_24528_89_1
SYS_PLSQL_57128_96_1
SYS_PLSQL_1345803_89_1

This happens only when Clarity is running on Oracle and the database schema name is not called niku, this can be safely ignored