User Abend U4093 CEE5101C During Initialization, The Callable Service BPX1MSS Failed.
search cancel

User Abend U4093 CEE5101C During Initialization, The Callable Service BPX1MSS Failed.

book

Article ID: 60227

calendar_today

Updated On:

Products

Cleanup Datacom DATACOM - AD CIS COMMON SERVICES FOR Z/OS 90S SERVICES DATABASE MANAGEMENT SOLUTIONS FOR DB2 FOR Z/OS COMMON PRODUCT SERVICES COMPONENT Common Services CA ECOMETER SERVER COMPONENT FOC Easytrieve Report Generator for Common Services INFOCAI MAINTENANCE IPC UNICENTER JCLCHECK COMMON COMPONENT Mainframe VM Product Manager CHORUS SOFTWARE MANAGER CA ON DEMAND PORTAL CA Service Desk Manager - Unified Self Service PAM CLIENT FOR LINUX ON MAINFRAME MAINFRAME CONNECTOR FOR LINUX ON MAINFRAME GRAPHICAL MANAGEMENT INTERFACE WEB ADMINISTRATOR FOR TOP SECRET Xpertware Top Secret Top Secret - LDAP Top Secret - VSE

Issue/Introduction

Receiving a user abend 4093 with a batch  job using ACID 'USERA' with error message:

CEE5101C During initialization, the callable service BPX1MSS failed. The system return code was 0000000156, the reason code was 0B0C00FC. The application will be terminated.

 

Environment

Release: TOPSEC00200-16-Top Secret-Security
Component:

Resolution

 CEE5101C rc=156, reason=0B0C00FC BPX1MSS

means the ACID is missing OMVS segments.