Description:
Gigastor Reader service not starting getting Error Message 1067: The process terminated unexpectedly
<Please see attached file for image>
********** GigastorSuperAgentSource **********
13:16:10 Severity 1 - GigastorSuperAgentSource starting up
13:16:39 Severity 1 - GS Initialize() failed (errror = -1) after 30 retries.
13:16:39 Severity 2 - hr_test failure 0x80004005 Unspecified error at .\GigastorReader.cpp 390
13:16:39 Severity 2 - hr_test failure 0x80004005 Unspecified error at .\GigastorReader.cpp 174
13:16:39 Severity 2 - Aborting service
Solution:
The Observer/Expert Probe MUST be up and running as a service first.
When running as an Observer Application it is not running as a service.
You must switch the Observer to Expert Probe then select to run as a service.
Expert Probe on a GigaStor
<Please see attached file for image>
Options screen.
<Please see attached file for image>
If all services are running and you're still not getting any data or Active Sessions, run the Digest Receiver on the server that the Gigistor is sending to. Verify that data is being received. If it is no data is being received then check the firewalls.