Gen HE install job CEJOB10 fails with message TIEC086E
search cancel

Gen HE install job CEJOB10 fails with message TIEC086E

book

Article ID: 43568

calendar_today

Updated On:

Products

Gen Gen - Host Encyclopedia

Issue/Introduction

Failure of Gen Host Encyclopedia (HE) job CEJOB10 “Load required functions model to a new encyclopedia”
The error message displayed is:
TIEC086E NO LONGER SUPPORT 8.0.A3 MODELS OR EARLIER. CANNOT UPLOAD.

Environment

Gen Host Encyclopedia

Resolution

CEJOB10 loads the Schema Functions Model.
1. The TIEC086E error is normally due to dataset prefix or suffix naming problems:
a. Check if an incorrect value is set for the suffix names for "Data (EGEN/TRAN)" (Default: CEHBDATV) and "X-Late Tables" (Default: CEHBDATB) on the "Installation Variables Management"/"Set library names" screen:
Configuring Host Encyclopedia and Host Construction > Establish the Environment > Tasks to Define Installation Variables

b. Check suffix names and also validate dataset prefix/HLQ are all correct in PARMLIB members TIUHE, TIUHE2 e.g. TIUHE contains "TIUXLAT=HLQ.XXX.CEHBDATB"

2. After correcting any "Installation Variables Management"/"Set library names" problems save as updated JCL member TILPARMS and rebuild the PARMLIB (parameter file) members:
Configuring Host Encyclopedia and Host Construction > Establish the Environment > Build Parameter File

3a. Check that the "X-Late Tables" dataset contains the expected number of members. For Gen 8.6 there should be 2462 members starting with AAAAAAAB and ending with OGIIOGHK. If not correct can copy/redeploy from SMP/E CSI CEHBDATB.
b. Check that the "EGEN/TRAN" dataset contains the expected number of members. For Gen 8.6 there should be 24 starting with FUNCMODL and ending with SAMPMODL. If not correct can copy/redeploy from SMP/E CSI CEHBDATV.

4. Re-run the CEJOB10 job

Additional Information