Network I/O admission control (NIOC) check failed for Ethernet device(s): 1(bitMap).
Check the host network configuration for available bandwidth for reservation.
Failed to start the virtual machine.
Module NIOC power on failed.
VMware vCenter Server
VMware vSphere ESXi
There are two potential causes for a VM power-on failure due to NIOC. This KB is specific to 'Cause 2' below:
Cause 1
ENS-Polling mode does not support more than 108 VMs per vSwitch:
Cause 2
NIOC is not supported by smartNICs.
This is a known issue impacting VMware NSX.
Cause 2 Workaround
1. Remove ethernetX.share, ethernetX.reservation and ethernetX.limit from the .vmx file of impacted VMs: