After upgrading to CA Panvalet V14.6, a 77 PAN-VALET line is being inserted into Working Storage of COBOL programs. Why?
search cancel

After upgrading to CA Panvalet V14.6, a 77 PAN-VALET line is being inserted into Working Storage of COBOL programs. Why?

book

Article ID: 4057

calendar_today

Updated On:

Products

Database Analyzer (IMS Tools) Mainframe Configuration Manager for IMS for z/OS IMS TOOLS - MISC Compress Data Compression (IMS Tools) Database Analyzer for IMS for z/OS Database Copier for IMS for z/OS Database Organizer for IMS for z/OS Mainframe Extended Terminal Manager (IMS Tools) High Performance Recovery for IMS for z/OS Database Organizer (IMS Tools) Mainframe Program Restart Manager for IMS for z/OS Secondary Index Builder for IMS for z/OS Secondary Index for IMS for z/OS JARS JARS Resource Accounting JARS SMF Director JMR MIM Resource Sharing (MIM) MIM Data Sharing (MII) MIM Tape Sharing (MIA) MIM Message Sharing (MIC) Nastel AutoPilot for WebSphere MQ Panvalet QuickFetch Raps VSE Scheduler VSE SMR SOLVE:Operations Automation SOLVE:Access Session Management SOLVE:FTS SYSVIEW Performance Management NXBRIDGE - SYSVIEW/ENDEVOR SOLVE

Issue/Introduction

After upgrading to CA Panvalet V14.6, a 77 PAN-VALET line is being inserted into Working Storage of COBOL programs.  Why?

Environment

z/OS

Cause

In Panvalet V14.6 the Load Module Auditor Extended Feature was mistakenly distributed activated in the PANEXIT module. 

Panvalet Load Module Auditor inserts extra lines in COBOL Working Storage that start with: 77 PAN-VALET PICTURE X(24) VALUE.....

It also inserts a similar CSECT at the end of Assembler programs. 

 

Resolution

Download and Apply PTF RO25651 from CA Support Online.

Additional Information

The Load Module Auditor is documented in Chapter 3: Extended Features of the CA Panvalet Extended Features Guide.