Is it possible to stop or delete disable autowatches from the Spectrum OneClick Console that were configured in sysedge
book
Article ID: 32913
calendar_today
Updated On:
Products
CA Spectrum
Issue/Introduction
Is it possible to stop, delete or disable autowatches from the Spectrum OneClick Console that were configured in sysedge?
Environment
Release:
Component:
Resolution
Autowatches created in sysedge cannot be disabled via the Spectrum OneClick Console.
If the autowatcher is configured in the sysedge.cf, you should not modify the generated monitors in OneClick.
If you do, the autowatcher directive will likely re-create/update them based on its criteria.
Either don´t use the autowatcher, or use the additional criteria to exclude filesystems that you do not want to monitor.