CA Gen: Running a GUI C application fails to execute.
search cancel

CA Gen: Running a GUI C application fails to execute.

book

Article ID: 29073

calendar_today

Updated On:

Products

Gen Gen - Workstation Toolset Gen - Run Time Distributed

Issue/Introduction

When running a GUI C application, the following 2 different error messages may have the same root cause:

'Could not register IEFWINOW class'

<OR>

'No DBMS Stub Executable has stopped working.'

 

Resolution

The errors are caused by having a Gen 8.0 deployment directory successfully running and then creating Gen 8.5 Load Module DLLs and putting them into the Gen 8.0 directory.  A flow from a 8.0 Application DLL will not work to a 8.5 Application DLL and vice versa. Separate directories must be created for each version of a Gen GUI C deployment and application flows cannot occur between these different releases.