UIM 23.4 OC and primary hub become intermittently unresponsive
search cancel

UIM 23.4 OC and primary hub become intermittently unresponsive

book

Article ID: 279762

calendar_today

Updated On:

Products

DX Unified Infrastructure Management (Nimsoft / UIM)

Issue/Introduction

After upgrading to 23.4 the hub goes down/becomes unreachable/cannot log in intermittently. After a service restart the issue is resolved but the issue reappears again. 

This affects the whole UIM, alarm processing and monitoring from the OC. 

Service Restart fixes the issue

When the issue occur, administrator cannot log in to the UIM with the error message: "Canot locate specified domain"

Environment

DX UIM 23.4 GA

Cause

Anti-Virus scanning UIM install folder can cause these issues

Resolution

The issues described might be caused by an AntiVirus or Security Software that prevents some UIM operations, actually blocking the workflow. 

Ensure the DX UIM Install Folder is excluded from the AntiVirus scan on both the primary hub and OC servers.