After importing data to Automic which included LOGIN objects, the passwords for those LOGIN objects have all been changed.
When running a task that requires a LOGIN object, the task does not start, and in the Process Monitoring perspective it shows the status for the task of
FAULT_OTHER - Start impossible. Other error.
Release : 12.3.x, 21.x
Component :
When exporting a LOGIN object, the password field is blanked out.
This is by design for security.
Using Export and Import for a LOGIN object does not export the password, and therefore an import will set the password for the object as 'blank'.
The only way to transfer a LOGIN object with the password intact is to use Transport Case, as this pulls the data directly from the database and is not shown in plain text in the uc_data.txt file created by the Transport Case process.